background image

4.1   FRONT  PANEL(2U)

2

PROT

TEMP

4

6

8

10

12

OUTPUT LEVEL

POWER

MIC 1

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

BASS

0

-5

-4

-3

-2

-1

+1

+2

+3

+4

+5

TREBLE

0

-5

-4

-3

-2

-1

+1

+2

+3

+4

+5

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

MIC 3

AUX 1

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

AUX 2

MIC 1

MIC 2

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

MASTER

5

 0

 1

 2

 3

 4

 6

 7

 8

 9

10

ON

OFF

2

3

7

4

5

6

8

1

9

10

11

6

4. NOMENCLATURE AND FUNCTIONS

 

1.    
       

2.    

 

       

3.      

        

4.     

       

5.     

        

    

MIC1

MIC1 input 6.3 Microphone jack input

MIC1 \ MIC2 \ MIC3

MIC volume control

AUX1 \ AUX2     

AUX volume control

BASS

Adjust bass response. Rotate clockwise

       to increase bass output and anticlockwise 
       to reduce it.  

TREBLE 

 

Adjust treble response. Rotate clockwise 

       to increase treble output and anticlockwise 
       toreduce it.

6.    MASTER

       

Master volume controls all size of input 

       signal level.

7.    POWER SWITCH

       On top of the opening Power         
       Press the end, power shut down  

8.    POWER

       

The power LED lights when it is turned on;

       the power LED lights out when it is turn off.

9.    LEVEL INDICATORS
       

Level meters 6 output level indicators

10.  PROT
       

When the machine is in protection status,

       this indicator will be lit: in normal operation
       status, the LED is off. If the product is in 
       protection status due to overheating, 
       overload or direct current, the indication 
       LED will be lit while the output relay will be 
       disconnected. (Signal indicator is just used 
       to indicate the use of input music signal.
       In the protection status, signal indicator is 
       still lit according to the size of input signal.)

11.   TEMP
        

When the machine is overloaded and 

       overheated, the indicator will be lit. when it
       works normally, this indicator will be off.

    

Содержание T-120B

Страница 1: ...3 2 1 1 2 3 4 5 TREBLE 0 5 4 3 2 1 1 2 3 4 5 5 0 1 2 3 4 6 7 8 9 10 MIC 3 AUX 1 5 0 1 2 3 4 6 7 8 9 10 AUX 2 MIC 1 MIC 2 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 MASTER 5 0 1 2 3 4 6 7 8 9 10 ON...

Страница 2: ...FUNCTIONS 4 1 Front Panel 2U 6 4 2 Rear Panel 2U 7 4 3 Rear Panel 24V 2U 7 4 4 Front Panel 3U 8 4 5 Rear Panel 3U 9 4 6 Rear Panel 24V 3U 9 5 CONNECTIONS 10 6 11 7 APPLICATIONS 12 8 BLOCK DIAGRAM 14 9...

Страница 3: ...as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these te...

Страница 4: ...in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause inju...

Страница 5: ...s from 60W to 650W 100V 70V line transformer isolated speaker outputs low impedance 4 16 ohms speaker outputs One EMC priority input Two aux input and two line input Two balanced mic inputs and three...

Страница 6: ...uce it 6 MASTER Master volume controls all size of input signal level 7 POWER SWITCH On top of the opening Power Press the end power shut down 8 POWER The power LED lights when it is turned on the pow...

Страница 7: ...rminal which could be connected with negative terminal and the ground wire 4 16 terminal is used to connect the speaker with impedance 4 16 70V terminal is used to connect the speaker with 70V 100V te...

Страница 8: ...se toreduce it 6 MASTER Master volume controls all size of input signal level 7 POWER SWITCH On top of the opening Power Press the end power shut down 8 POWER The power LED lights when it is turned on...

Страница 9: ...ch could be connected with negative terminal and the ground wire 4 16 terminal is used to connect the speaker with impedance 4 16 70V terminal is used to connect the speaker with 70V 100V terminal is...

Страница 10: ...5 2 XLR CONNECTIONS 4 16 5 CONNECTIONS 70V 70V 100V COM 4 16 100V LINE T 60B T 120B T 240B 166 7 83 3 41 6 T 350B 20 6 T 550B 18 1 T 650B 15 3 10 70V 100V COM 4 16 70V LINE T 60B T 120B T 240B 81 6 4...

Страница 11: ...re the total power wattage of speaker is 15 less than the power wattage of amplifier GUIDANCE OF EXCLUDING ERRORS 6 MACHINE OPERATION 11 1 Machine is in protection condition in case of high temperatur...

Страница 12: ...MIC 3 48V PHANTOM AUX2 INPUT MIX OUT AUX1 INPUT MIC2 MIC3 LINE INPUT COM COM MIC2 MIC3 MIC 2 MIC 3 MIC 2 XLR GAIN MIC 3 XLR GAIN MIC 2 MIC 3 USE ONLY WITHA 250V FUSE ALARM IN ALARM OUT MIC IN REC IN A...

Страница 13: ...INPUT MIC2 MIC3 LINE INPUT MIC 3 XLR GAIN EMC INPUT 70V COM 4 16 100V OUTPUT COM COM REAR PANEL CONNECTIONS 13 APPLICATIONS SPEAKERS MIC 2 MIC 3 USE ONLY WITHA 250V FUSE ALARM IN ALARM OUT MIC IN REC...

Страница 14: ...8 BLOCK DIAGRAM 14 MIX OUT 100V 70V 4 TO PA BASS TREBLE VOLUME PROTECT LEVEL INDICATOR POWER Z AC 220 240V 50 60Hz PT EB MIC1 COM MUTE EB EMC EB EB EB EB AUX1 EB AUX2 MUTE MASTER MIC3 LINE1 LINE1 MIC2...

Страница 15: ...ntrols power switch The built in cooling fan will be automatically starts when the temperature of inside power modular is up to 55 degrees loverheating protection short circuit protection and overcurr...

Страница 16: ...er 50dB MIC 1 over other input signals with 0 30dB attenuation except MIC 1 Individual gain controls power switch The built in cooling fan will be automatically starts when the temperature of inside p...

Страница 17: ...29 321 88 94 436 484 17 UNIT mm UNIT mm COM4 16 70V 100V USE ONLY WITHA 250VFUSE EMC INPUT 1 2 3 1 2 3 MUTE OUTPUT MIC 2 48V PHANTOM MIC 3 48V PHANTOM AUX2 INPUT MIX OUT AUX1 INPUT MIC2 MIC3 LINE INPU...

Страница 18: ...SS 0 5 4 3 2 1 1 2 3 4 5 TREBLE 0 5 4 3 2 1 1 2 3 4 5 5 0 1 2 3 4 6 7 8 9 10 MIC 3 AUX 1 5 0 1 2 3 4 6 7 8 9 10 AUX 2 MIC 1 MIC 2 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 MASTER 5 0 1 2 3 4 6 7 8...

Страница 19: ...PUBLIC ADDRESS SYSTEM VersionV0 4...

Отзывы: