ITC Chocolate- 777 Скачать руководство пользователя страница 8

 

 

 

 

LOCATION AND SUPPORT CONSIDERATIONS

 

 

Select a level location where the floor structure beneath the Pedicure Spa is capable of supporting it. 

 

NOTE

: if one requires the seat back to recline to its maximum, the base of the Pedicure Spa must be a minimum of 18” 

(44 cm) clear from the back wall. If the distance is less, the seat back may still recline, however it will hit the back wall 
and damage the seat and/or the massage mechanism. 

 

PLUMBING CONNECTIONS

 

 

All plumbing connections for drain and supply water MUST be performed by a qualified, licensed plumber in 

accordance with local plumbing and building codes 

 

A) 

HOT AND COLD WATER SUPPLY LINES 
Carefully connect supply water to the ½” supply nipples (shut off valves should be utilized. 

 

B) 

CONNECT DRAIN WITH DISCHARGE PUMP 
Using ¾” schedule 40 PVC drain pipe and appropriate traps to connect drain to meet local 

plumbing codes. 

 

C) 

CONNECT DRAIN WITHOUT DISCHARGE PUMP 
Using 1-1/4” schedule 40 PVC drain pipe and appropriate traps, connect drain to meet local 
plumbing codes. 

Attention: In some areas local codes require back-flow prevention to be installed in compliance with 
248 CM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL CONNECTIONS & WIRING INSTRUCTIONS

 

 

All electrical connections MUST be performed by a qualified, licensed electrician in accordance with local and building 
codes. A 15 Amp, GFCI protected grounded circuit MUST be used to supply power to the Pedicure Spa. A dedicated 

circuit must be provided with a GFCI. All wiring must conform to National & Local Electrical Codes. 

 

 

IT IS EXTREMELY IMPORTANT THAT THE PEDICURE SPA OPERATES WITH A GFCI PROTECTION

 

OPERATION & CARE INSTRUCTIONS

 

 

 

 

 

Содержание Chocolate- 777

Страница 1: ...Whirlpool Spa BEFORE OPERATING THE UNIT MUST CAREFULLY READ AND UNDERSTAND THIS MANUAL RETAIN THIS MANUAL FOR FUTURE REFERENCE CHOCOLATE PEDICURE SPA OWNER S MANUAL CHOCOLATE WHIRLPOOL SPA by ITC INTERNATIONAL TRADING INC USA ...

Страница 2: ...View _ 6 Location Support Plumbing Connections Electrical Connections 7 Gravity Drain Diagram 8 Power Drain Diagram 9 Operation Care Instructions Getting Started Shutting Down Maintenance 10 Cleaning Instructions 11 Specifications 12 Warranty Terms and Conditions 13 Seat Massage Instructions See Attached Additional Operation Instruction 1 ...

Страница 3: ... conditions should not use this massage if desired user should consult with a physician prior to using this appliance Malignant Tumor Pregnancy Heart Problem Back Neck Pain Not in Good Conditions CAUTION RISK OF ELECTRICAL SHOCK ALL RECEPTACLES LOCATED WITHIN FIVE 5 FEET OF THIS DEVICE SHALL BE PROTECTED BY A GROUND FAULT INTERRUPTER GFI RISK OF ELECTRICAL SHOCK CONNECT ONLY TO A PROPER GROUDED GR...

Страница 4: ...3 ...

Страница 5: ...4 ...

Страница 6: ...5 ...

Страница 7: ...6 ...

Страница 8: ...off valves should be utilized B CONNECT DRAIN WITH DISCHARGE PUMP Using schedule 40 PVC drain pipe and appropriate traps to connect drain to meet local plumbing codes C CONNECT DRAIN WITHOUT DISCHARGE PUMP Using 1 1 4 schedule 40 PVC drain pipe and appropriate traps connect drain to meet local plumbing codes Attention In some areas local codes require back flow prevention to be installed in compli...

Страница 9: ...8 ...

Страница 10: ...9 ...

Страница 11: ...ssive foaming SHUTTING DOWN 1 Push press air switch button to turn off jet s 2 Turn drain control knob and check water stopper is opened 3 If your spa has a water discharge pump turn on to drain out water remember to turn off pump 4 Sanitize tub per local and state requirements IMPORTANT NOTE Water discharge pump must be turned OFF after water had drained out DO NOT let it runs dry MAINTENANCE A q...

Страница 12: ...etergent product and circulate the detergent through the spa system for at least 10 minutes follow manufacture s instructions 2 Drain the detergent solution and rinse the basin 3 Refill the basin with clean water and circulate the correct amount read the label for mixing instructions of the EPA registered hospital liquid disinfectant which the label claims is a bactericide fungicide and virucide t...

Страница 13: ...GE PUMP optional 115V 60HZ OPERATING VOLTAGE 120V 1 5AMP 60 HZ PIPELESS JET 1 25A 115VAC 0 1HP WEIGHT 190 LBS ACCESSORIES PEDICURIST STOOL CHAIR MASSAGE ROUTE 450M M RECLINING ROUTE 110 140 DEGREES POWER AC 120V 60HZ RATED TIME 10 20 30 MINUTES DIMENSION 44 L X 32 W X 18 H WEIGHT 110 LBS 12 ...

Страница 14: ...s warranty is valid only in the continental of United State of America Proof of purchase in the form of Bill of Sale Receipt Invoice which is evidence that the unit is within the warranty period must be presented to obtain warranty service This warranty is null and void if the spa is not installed in accordance with federal state and local codes and ordinances Furthermore this warranty does not ap...

Отзывы: