background image

 

PROCEDURES FOR CLEANING AND DESINFECTION PIPE-LESS FOOT SPAS

 

Please comply with your state board cleaning and disinfecting procedures 

 

a) 

“Pipe-less” foot spa is defined as any unit with footplates, impellers, impeller assemblies and propellers. 

b) 

After use upon each patron, each foot spa shall be cleaned and disinfected in the following sequential 

manner: 

1)  All water shall bed rained from the spa basin 

2) 

Remove jet cover by turning counter-clockwise 

3) 

Scrub all visible residues from the impeller, inside walls of the basin, and/or other components and 

the areas behind or under each with a clean brush and liquid soap (labeled as such on soap 

product) and water. Rinse with clean water 

4) 

Reinsert the properly cleaned jet cover 

5) 

Refill the basin with clean water and circulate the correct amount (read the label for mixing 
instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a 

bactericide, fungicide, and virucide, through the basin for at leas 10 minutes 

6) 

Drain, rinse and wipe the basin dry with a clean paper towel 

7) 

Record this procedure in a Pedicure-Cleaning Log. The log shall contain the date and time of each 
cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning 

was done after a client 

c) 

At the end of each day and after performing the procedures provided in subsection (b) (1 through 7) and 

after the last client, each foot spa shall be cleaned and disinfected in the following sequential manner: 

1)  Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate 

the detergent through the spa system for at least 10 minutes (follow manufacture’s instructions) 

2)  Drain the detergent solution and rinse the basin 

3)   

Refill the basin with clean water and circulate the correct amount (read the label for mixing 
instructions) of the EPA-registered hospital-liquid disinfectant which the label claims is a 

bactericide, fungicide, and virucide, through the basin for at leas 10 minutes 

4)   

Drain, rinse and wipe the basin dry with a clean paper towel 

5)   

Allow the basin to dry completely 

6) 

Record this procedure in a Pedicure-Cleaning Log. The log shall contain the date and time of each 

cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning 
was done after at the end of the day 

d) 

At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and 
the disinfectant solution in each foot spa shall not be drained and the following sequential procedures 

shall be followed: 

1)  The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 

10 hours 

2)   

After the disinfectant solution has been sitting between 6 to 10 hours, rinse and wipe the basin dry 

with a clean paper towel 

3)   

Record this procedure in a Pedicure-Cleaning Log. The log shall contain the date and time of each 
cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning 

was done weekly 

e) 

The pedicure-cleaning log shall be made available upon request by either a patron or a board 
representative 

f) 

A violation of this section may result in an administrative fine and/or disciplinary action. Each foot spa 

not in compliance with this section may result in a separate violation 

 

 

 

 

 

 

 

 

 

 

 

 

11 

Содержание Chocolate- 777

Страница 1: ...Whirlpool Spa BEFORE OPERATING THE UNIT MUST CAREFULLY READ AND UNDERSTAND THIS MANUAL RETAIN THIS MANUAL FOR FUTURE REFERENCE CHOCOLATE PEDICURE SPA OWNER S MANUAL CHOCOLATE WHIRLPOOL SPA by ITC INTERNATIONAL TRADING INC USA ...

Страница 2: ...View _ 6 Location Support Plumbing Connections Electrical Connections 7 Gravity Drain Diagram 8 Power Drain Diagram 9 Operation Care Instructions Getting Started Shutting Down Maintenance 10 Cleaning Instructions 11 Specifications 12 Warranty Terms and Conditions 13 Seat Massage Instructions See Attached Additional Operation Instruction 1 ...

Страница 3: ... conditions should not use this massage if desired user should consult with a physician prior to using this appliance Malignant Tumor Pregnancy Heart Problem Back Neck Pain Not in Good Conditions CAUTION RISK OF ELECTRICAL SHOCK ALL RECEPTACLES LOCATED WITHIN FIVE 5 FEET OF THIS DEVICE SHALL BE PROTECTED BY A GROUND FAULT INTERRUPTER GFI RISK OF ELECTRICAL SHOCK CONNECT ONLY TO A PROPER GROUDED GR...

Страница 4: ...3 ...

Страница 5: ...4 ...

Страница 6: ...5 ...

Страница 7: ...6 ...

Страница 8: ...off valves should be utilized B CONNECT DRAIN WITH DISCHARGE PUMP Using schedule 40 PVC drain pipe and appropriate traps to connect drain to meet local plumbing codes C CONNECT DRAIN WITHOUT DISCHARGE PUMP Using 1 1 4 schedule 40 PVC drain pipe and appropriate traps connect drain to meet local plumbing codes Attention In some areas local codes require back flow prevention to be installed in compli...

Страница 9: ...8 ...

Страница 10: ...9 ...

Страница 11: ...ssive foaming SHUTTING DOWN 1 Push press air switch button to turn off jet s 2 Turn drain control knob and check water stopper is opened 3 If your spa has a water discharge pump turn on to drain out water remember to turn off pump 4 Sanitize tub per local and state requirements IMPORTANT NOTE Water discharge pump must be turned OFF after water had drained out DO NOT let it runs dry MAINTENANCE A q...

Страница 12: ...etergent product and circulate the detergent through the spa system for at least 10 minutes follow manufacture s instructions 2 Drain the detergent solution and rinse the basin 3 Refill the basin with clean water and circulate the correct amount read the label for mixing instructions of the EPA registered hospital liquid disinfectant which the label claims is a bactericide fungicide and virucide t...

Страница 13: ...GE PUMP optional 115V 60HZ OPERATING VOLTAGE 120V 1 5AMP 60 HZ PIPELESS JET 1 25A 115VAC 0 1HP WEIGHT 190 LBS ACCESSORIES PEDICURIST STOOL CHAIR MASSAGE ROUTE 450M M RECLINING ROUTE 110 140 DEGREES POWER AC 120V 60HZ RATED TIME 10 20 30 MINUTES DIMENSION 44 L X 32 W X 18 H WEIGHT 110 LBS 12 ...

Страница 14: ...s warranty is valid only in the continental of United State of America Proof of purchase in the form of Bill of Sale Receipt Invoice which is evidence that the unit is within the warranty period must be presented to obtain warranty service This warranty is null and void if the spa is not installed in accordance with federal state and local codes and ordinances Furthermore this warranty does not ap...