INSTALLATION TO THE START UP 

 

For any questions or technical problems you may encounter during the installation phase, the ITALAB technical 
staff will  be  at  your  complete   disposal to  solve the  problem. Please do not produce  any  change  that  may 
damage the Device . 
 
Before mounting the Amplifier, check that in the room intended for the installation: 

• 

dust  is not excessive 

• 

no  deposits of harsh chemicals are present (chlorine, sulfur, etc..) 

• 

any heat source (radiators, hot air ventilation etc.) must be at least 2 meters; 

• 

the  room  temperature  must  not exceed the  limits between  0 and  +40 ° C  with  a relative  humidity  no 
higher than 90% non-condensing. 
 

After removing the Amplifier out of the packaging, verify that no damages have occurred during shipment.

 

Electrical connections 

• 

The connection with main power at 230 Vac must be done through the cable shipped with the Amplifier 
or with a three conductor cable and minimum conductor section 2.5 mm square.  

• 

For  safety  is  a  good  rule  to  have  a  dedicated  cord  of  2.5  mm  square  coming  from  main  panel  to  wall 
outlet with a proper thermal-magnetic circuit breaker. 

• 

Check that the ON/OFF switch on the rear panel of Amplifier is on OFF position 

• 

Plug the AC power cord into the AC power socket on the rear panel of Amplifier 

• 

Plug the other end of the AC power cord into a wall outlet 

• 

Connect the AC power cord of the exciter to the female wall outlet on the rear panel of Amplifier. This is 
powered only when the Amplifier is in broadcasting mode. 

• 

The max power absorption allowed is 230W/1A   

RF connection 

• 

Connect  the coaxial  antenna cable  with impedance of 50 

Ω

  to  the RF output connector ( 7/16” ) on the 

rear panel of Amplifier  

• 

Connect the RF output  of exciter to RF input connector  of Amplifier with coax cable with impedance of 
50 

Ω

  

 

Final check for start-up procedure 

Before starting the procedure check the following points for security: 
 

 
 
 

 

That the Amplifier has the GROUND connection 

That the Vac  230 with its circuit breaker is correctly connected to the Amplifier 

That the AC power cord of exciter is correctly connected to the Amplifier 

That the antenna cable is correctly connected at the Amplifier 

That the RF cable from exciter to the Amplifier is correctly connected 

Verify that the input power is not greater than 2 watts. The device will maintain constant the 
output power even in the presence of a greater power input. Excessive power input will 
damage the Equipment. 

 

 

Содержание ARCHIMEDE 3000

Страница 1: ...20144 Milano Italy Phone 39 02 90389417 Fax 39 02 23168389 E mail info italab it Website www italab it ITALAB reserves the right to revise and change any and all information included in this document...

Страница 2: ...ab and clearly explain the nature of your problem Once we acknowledge your Equipment needs service we will send you an electronic form to fill in with your name address phone number e mail and an accu...

Страница 3: ...t up 12 System block diagram and Internal Connections 13 Circuit description 14 15 RF amplifier box CPU board Analog board Led board Lcd display Power supply 14 14 15 15 15 15 LCD display screens 16 P...

Страница 4: ...he Amplifier is powered by any other source make sure that the chassis is connected to a separate safety ground DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Operation of the ARCHIMEDE 3000 in presence of...

Страница 5: ...cabinet that may stop the flow of air through the ventilation openings All plugs on the connection cables must be screwed or locked to the chassis housing The device is designed to be used in horizon...

Страница 6: ...AMP1000 FM that can deliver full power to 3750 watts in continuous service However since the philosophy of Italab is to allow all components of a product not to work in stressful conditions the full...

Страница 7: ...25 A 230Vac Protections Overload VSWR and Temperature Cooling Forced Air Working Ambient Temperature 0 40 C Storage Temperature 10 60 C Umidity 90 Control System 2 buttons 4x20 LCD display Dimension 3...

Страница 8: ...iting the output power in order not to exceed the nominal power Steady light indicates that the output power is greater than the nominal power LED TEMP Steady light indicates that the sensors placed i...

Страница 9: ...Hot air extraction from power supply option 2 RF Output Connector 3 RF Input Connector 4 220 Vac control output for the transmitter Max 1 A 5 Ground connector 6 A C mains input 220 Volt 7 A C mains i...

Страница 10: ...User s Manual ARCHIMEDE 3000 AR 432 Page 10 of 40 INTERNAL OVERVIEW OF EQUIPMENT 3 2 1 6 5 4 1 COLD AIR INPUT GRID option 2 COLD AIR INPUT VANS 3 RF BOX 4 INTERFACE RF BOX 5 6 CPU POWER SUPPLIES these...

Страница 11: ...hermal magnetic circuit breaker Check that the ON OFF switch on the rear panel of Amplifier is on OFF position Plug the AC power cord into the AC power socket on the rear panel of Amplifier Plug the o...

Страница 12: ...ng performed the stop procedure because if the Amplifier is still connected to input power when is removed this could damage the Equipment The installation of the Amplifier is now completed and the co...

Страница 13: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 13 of 40 SYSTEM BLOCK DIAGRAM INTERNAL WIRING...

Страница 14: ...r designed to allow an immediate access and inspection to all internal modules All the RF part is completely screened by an Alodyne Aluminium to comply with EMI requirements 2 CPU BOARD MICROPROCESSOR...

Страница 15: ...ED BOARD On this board are placed some led for warning alarm status machine and two buttons mainly used to start stop the Equipment and as second function to read change the Equipment parameters 5 LCD...

Страница 16: ...h m m START of TRANSMISSION After pushing the start button or turning on the Amplifier placed on start after the setup stage the display will show the written A R C H I M E D E 3 0 0 0 W a i t S y s t...

Страница 17: ...will activate the standby procedure The display will show the written at the same time will be disconnected the AC power from aux main plug located on the rear panel and the voltage polarization on th...

Страница 18: ...quence If at the end of the sequence the PWR is inside the limit the transmission will continue otherwise it will fall back into the alarm cycle Warning If the alarm cycle is repeated for 5 times in a...

Страница 19: ...some seconds the main power supply 230 Volt and then turn it on Please check if the output impedance is 50 Ohm TEMPERATURE ALARM When the CPU detects that a temperature sensor provides a value above t...

Страница 20: ...how the written P a s s w o r d At this point insert the password as follows push for 3 times the stop button push for 3 times the start button Whenever you press a button the display will show the sy...

Страница 21: ...ter the programming clock menu and the display will show the written P r o g r a m m i n g C L O C K h h m m g g m m a a a a By pressing the stop button you increase the time when you reach the correc...

Страница 22: ...go to the programming language menu and the display will show the written P r o g r a m m i n g L A N G U A G E E N G L I S H By pressing the stop button the languages supported English French Spanis...

Страница 23: ...age P r o g r a m m i n g L A N G U A G E I T A L I A N O After the choice on the display will show the written in the selected language P r o g r a m m i n g L A N G U A G E In this situation by pres...

Страница 24: ...the start button you confirm this indication in each cell and it will pass automatically to the next cell Do the same operation for all 20 characters in the line At the end of the operation the displa...

Страница 25: ...HIMEDE 3000 AR 432 Page 25 of 40 P r o g r a m m i n g P R O G R A M M I N G E X I T P U S H S T A R T In this situation by pressing the stop button it switches to previous menu while by pressing the...

Страница 26: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 26 of 40 SCHEMATICS DRAWINGS AND BOM RF BOX...

Страница 27: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 27 of 40 CPU...

Страница 28: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 28 of 40...

Страница 29: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 29 of 40...

Страница 30: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 30 of 40...

Страница 31: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 31 of 40...

Страница 32: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 32 of 40...

Страница 33: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 33 of 40...

Страница 34: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 34 of 40 LED...

Страница 35: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 35 of 40...

Страница 36: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 36 of 40...

Страница 37: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 37 of 40 ANALOG...

Страница 38: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 38 of 40...

Страница 39: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 39 of 40...

Страница 40: ...Italian Technology of Broadcast User s Manual ARCHIMEDE 3000 AR 432 Page 40 of 40...

Отзывы: