* Glass pipe breakage
The technical features of the glass pipe are particular and such as to permit resistance to thermal shocks caused by normal
temperature fluctuations, rain or damp.
Despite the choice of this material (Borosilicate), sudden pipe breakages can occur as a result of particular weather conditions
and/or excessively concentrated temperature fluctuations.
IMPORTANT! This pipe breakage (crack) does not cause injury to people or damage to things in the immediate vicinity of the
appliance.
IMPORTANT! Any pipe breakage does not, in the short term, prevent the appliance from operating, but being a damaged part, it
must be replaced to ensure correct operation.
troUBleShootinG: manual controls.
No flame
1 – non enough gas supply flow:
- bad LPG gasification;
- bad LPG gasification with low temperature.
- pressure regulator wrongly set or faulty.
2 – sudden gust of wind (above 3 m/s).
3 – thermocouple interrupted.
4 – valve magnet faulty.
5 - Dump-switch failure or the floor with
inclination greater than 15
ϒ
.
6 – dirt in gas circuit.
7 – gas leaks.
8 – battery low.
9 – isolation of electrodes and/or faulty
cables.
1- Check:
- Check and replace empty tank;
- Replace with Propane gas tank.
- Regulate or replace.
2 – keep appliance out of wind.
3 - Replace.
4 - Replace.
5 - Replace, change position (floor with
inclination less than 15
ϒ
).
6 - Check and clean carefully.
7 - Check and eliminate leak.
8 - Replace.
9 - Replace.
Blackening of glass pipe
poor quality gas or gas unsuitable for winter
bad draught
mains cylinder (optional) out of
position/deformed
exchanger head dirty/damaged
burner dirty/damaged
use quality gas, preferably pure propane
particularly windy or no wind-protection KIT
reposition/replace/eliminate
clean/replace
clean/replace
Replace
Replace
Replace
Содержание Falo Evo
Страница 5: ...5 Fig 2 2178 878 639 1194 603 52 782 732 2178 878 712 639 1194 603 52 755 MIN 500 MIN 500 r max 2m ...
Страница 6: ...6 Fig 3 ...
Страница 8: ...8 1 3 1 2 3 1 5Volt stilo KAA AA AM3 1 5Volt ministilo K3A AAA AM4 2 3 1 2 3 4 1 Fig 4 Fig 5 Fig 6 ...
Страница 9: ...9 1 1 1 2 4 5 8 7 10 11 9 12 1 1 2 10 11 9 5 13 7 12 1 4 1 2 3 5 6 7 8 4 Fig 7 Fig 8 Fig 9 ...
Страница 10: ...10 NO YES Fig 10 Fig 11 Fig 12 ...
Страница 12: ...12 remote control control unit 1 2 3 4 5 12 11 10 6 7 8 9 7 step 8 1 7 step 10 3 Fig 15 Fig 16 ...
Страница 22: ...22 I EVENTUALI ANOMALIE E RIMEDI con telecomando ...
Страница 30: ...30 UK TROUBLESHOOTING with remote control ...
Страница 41: ...41 ES ...
Страница 51: ...51 F ...
Страница 52: ...3520300085 Rev 0 ...