![Italiana Camini MARIU Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/italiana-camini/mariu/mariu_installation-use-and-maintenance-manual_2094754016.webp)
- 16
-
ENGLISH
ENGLISH
HEATING SPECIFICATIONS
Hopper capacity
20
kg
Efficiency
89,2
%
Available power (max)
8
kW
Time between refuellings (min/max)
10/22
hours
Fuel consumption (min/max)
0,9/2,0
kg/h
Heatable room dimensions *
190
m
3
Weight including packaging
155/172
kg
Smoke duct diameter (male)
80
mm
Air intake duct diameter (male)
40
mm
N.B.
1) bear in mind that external devices may cause interference.
2) caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL SPECIFICATIONS
Power supply
/- 10% 50 Hz
On/off switch
yes
Average power consumption
150
W
Power consumption during ignition
400
W
Remote control frequency (optional extra)
infrared
Protection on mains power supply **
2A, 250 Vac 5x20 Fuse
Electronic circuit board protection
2A, 250 Vac 5x20 Fuse
SAFETY DEVICES:
THERMOCOUPLE:
On the smoke outlet. It measures the smoke temperature.
It controls the ignition, operating and shutdown stages according to
the parameters set.
AIR FLOW SENSOR:
On the intake duct. It trips when the flow of combustion air is not
correct, therefore causing low pressure problems in the smoke
circuit.
SAFETY THERMOSTAT:
It trips if the temperature inside the stove is too high.
It stops pellet loading, thus causing the stove to go out.
The Dealer can install an optional on the AUX outlet
for controlling the process of switching on and off
(e.g. telephone remote, local thermostat), located at the
rear oh the stove. Can be connected via special optional
trestle (code 620550).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt
CR 2032 battery).
Its malfunction is indicated with the following messages:
(not considered a defect but due to normal wear-and-
tear): ERR 1 - ERR 2.
For more detailed information, please contact the DEA-
LER who has performed the first 1st ignition.
FUSE
* two fuses are inserted on the socket
behind the stove, fitted with a switch one
is functional and the other is spare.
*
*
SERIAL PORT
BACKUP
BATTERY
SMOKE
SPEED
THERMOCOUPLE
ROOM
SENSOR
P/TEMP.
ADJUSTMENT
VENTILATION
ADJUSTMENT
FLOW
SENSOR
MAINS
SCREW FEEDER
MOTOR
SMOKE EXTRACTION
MOTOR
VENTILATION
IGNITION HEATING
ELEMENT
SAFETY
THERMOSTAT
* The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation in
compliance with Italian law 10/91, and subsequent changes toge-
ther with an expected heat output of 35 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
AUX; if this does
not turn out SERIAL
PORT
Содержание MARIU
Страница 6: ...6 ITALIANO...