background image

 

30

Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather 
forecasting feature is estimated to have an accuracy level of about 75% due to the varying 
areas the Weather station has been designed for use. In areas that experience sudden 
changes in weather (for example from sunny to rain), the Weather station will be more 
accurate compared to use in areas where the weather is stagnant most of the time (for 
example mostly sunny). 

 

If the Weather station is moved to another location significantly higher or lower than its initial 
standing point (for example from the ground floor to the upper floors of a house), discard the 
weather forecast for the next 12-24 hours. By doing this, the Weather Station will not mistake 
the new location as being a possible change in air-pressure when really it is due to the slight 
change of altitude.  

 

WEATHER TENDENCY INDICATOR 

Working together with the weather icons is the weather tendency indicators (located on the 
left and right sides of the weather icons). When the indicator points upwards, it means that 
the air-pressure is increasing and the weather is expected to improve, but when indicator 
points downwards, the air-pressure is dropping and the weather is expected to become 
worse. 

 

Taking this into account, one can see how the weather has changed and is expected to 
change. For example, if the indicator is pointing downwards together with cloud and sun 
icons, then the last noticeable change in the weather was when it was sunny (the sun icon 
only). Therefore, the next change in the weather will be cloud with rain icons since the 
indicator is pointing downwards. 

 

Note:

 

 

Once the weather tendency indicator has registered a change in air pressure, it will remain 
permanently visualized on the LCD. 

 

AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC 
PRESSURE TREND) 

The third section of the LCD also shows the relative air pressure value and the air pressure 
history. 
 
 
 
 

 
 

The bar chart indicates the air pressure history trend over the last 24 hours in 7 steps, 0h, -
3h, -6h, -9h, -12h, -18h, and -24h. The “0h” represents the current full hour air pressure 
recording. The columns represent the “hPa” (0, ±2, ±4, ±6) at specific time. The “0” in the 
middle of this scale is equal to the current pressure and each change (±2, ±4, ±6) represents 
how high or low in “hPa“ the past pressure was compared to the current pressure. 

 

If the bars are rising it means that the weather is getting better due to the increase of air 
pressure. If the bars go down, it means the air pressure has dropped and the weather is 
expected to get worse from the present time “0h“. 

 

Note:   

For accurate barometric pressure trends, the Weather Station should operate at the same 
altitude for example, it should not be moved from the ground to the second floor of the 
house. Should the unit be moved to a new location, discard readings for the next 12-24 
hours. 

 
 
 

Air pressure over the last 24 hours 

Содержание WEATHER STATION

Страница 1: ...oduct is simple and straightforward By reading this operating manual the user will receive a better understanding of the Weather Station together with the optimum benefit of all its features FEATURES The Weather Station DCF Radio controlled time with manual setting option Time reception ON OFF user selectable 12 24 hour time display Time zone option 12 hours Battery compartment Hanging hole Instan...

Страница 2: ...Signal reception intervals at 4 seconds Can receive up to 3 outdoor transmitters LED back light Low battery indicator Table standing or wall mounting Thermo Hygro Transmitter Remote transmission of outdoor temperature and humidity to weather station by 868 MHz signals Wall mounting case TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION The Weather Station uses 3 x AA IEC LR6 1 5V batteries T...

Страница 3: ... them Once the indoor data is displayed user may proceed to the next step 3 After the batteries are inserted the Weather station will start receiving data signal from the transmitter The outdoor temperature and humidity data should then be displayed on the Weather station If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 4 In order ...

Страница 4: ...onal sensors is not followed as described above Should transmission problems occur it is necessary to remove the batteries from all units and start again the set up from step 1 RESETTING The Weather Station and the Thermo hygro transmitter need to be reset when one of the following conditions occur Unsuccessful 868MHz signal reception Malfunction on the units Batteries replacement For resetting re...

Страница 5: ...asy to use function keys SET key Press and hold the key to enter manual setting modes LCD contrast time zone time reception ON OFF 12 24 hour display manual time setting calendar temperature C F pressure hPa inHg relative pressure value and weather icon sensitivity setting Reset all MIN MAX records Stop the alarm during alarm ringing Stop snooze mode Back light on ALM DATE key Press and hold key f...

Страница 6: ...ot be shown on LCD The user can then easily see whether the last reception was successful icon on or not icon off On the other hand the short blinking of the icon shows that a reception is currently taking place MANUAL SETTINGS The following manual settings can be changed when pressing the SET key for LCD contrast setting Time zone setting Time reception ON OFF setting 12 24 hour format setting Ma...

Страница 7: ...ge runs from 0 to 12 and then runs from 12 back to 0 in consecutive 1 hour intervals 3 Confirm with the SET key and enter the Time reception ON OFF setting TIME RECEPTION ON OFF SETTING In area where reception of the DCF time is not possible the DCF time reception function can be turn OFF The clock will then work as a normal Quartz clock Default setting is ON 1 The digit ON will start flashing on ...

Страница 8: ... time into the received time During reception attempts the DCF tower icon will flash If reception has been unsuccessful then the DCF tower icon will not appear but reception will still be attempted the following day CALENDAR SETTING The date default of the Weather station is 1 1 2006 Once the radio controlled time signals are received the date is automatically updated However if the signals are no...

Страница 9: ... 35 30 72 inHg for a better reference 1 The current relative pressure value will start flashing 2 Use the OUT key to increment and IN key to decrement the value Keep holding the key allows the value to advance faster 3 Confirm with the SET key and enter the Weather forecast icon sensitivity setting WEATHER FORECASTING ICON SENSITIVITY SETTING For locations with rapid changes of weather conditions ...

Страница 10: ... is 2 minutes SNOOZE SETTING AND STOPPING THE ALARM 10 minutes snooze function can be set when the alarm is ringing by pressing the SNOOZE CH key When the alarm is snoozing the alarm icon will remain flashing indicating that the alarm is active but is in Snooze mode To stop the snooze function when it is in snooze period press any key except the SNOOZE CH key To stop the alarm press any key during...

Страница 11: ...of LCD can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air pressure has not changed or the change has been too slow for the Weather station to register However if the...

Страница 12: ...xample if the indicator is pointing downwards together with cloud and sun icons then the last noticeable change in the weather was when it was sunny the sun icon only Therefore the next change in the weather will be cloud with rain icons since the indicator is pointing downwards Note Once the weather tendency indicator has registered a change in air pressure it will remain permanently visualized o...

Страница 13: ...nsmitter 3 Three times to return to transmitter 1 2 Use OUT key to view the MIN MAX temperature and humidity data for the selected transmitter 3 To reset the minimum and maximum temperature and humidity data and the times at which they were recorded press the SET key continuously for about 3 seconds This will reset the MIN MAX data recorded to the current time date temperature and humidity The cur...

Страница 14: ...n space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up above POSITIONING THE WEATHER STATION The Weather station provides the option of table standing or wall mounting the unit Before wall mounting please check that the outdoor data can be received from...

Страница 15: ...atteries of the recommended type Do not make any repair attempts to the units Return it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS T...

Страница 16: ...he User manual is highly recommended for the benefit of the user The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This product is not to be used for medical purposes or for public information This product is only designed to be used in the home as indication of the future weather and is...