background image

C

 – The LED indicator provides the status of the hardware as follows:

·

Green – Powered on

·

Red – Power supply issue (e.g., burnt fuse

D

 – USB-C cable which is connected to the PC USB port. 

CAN 120 Ohm terminating resistor is not implemented on the DAP  over  CAN  Physical
Layer Converter. 

Содержание IEA-DXCPL

Страница 1: ...DAP over CAN Physical Layer User Manual V1 1 ...

Страница 2: ...ll rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Страница 3: ...Contents DAP over CAN Package content 5 Operation 6 winIDEA Configuration 8 Accessories 9 User Notes 10 User Notes 11 ...

Страница 4: ...all and compact hardware size allows for connecting to a target microcontroller in a confined space as far as 5m away Infineon AGBT Active Probe enables the debugging tracing and testing of Infineon s AURIX microcontroller family It supports the DAP and Aurora GigaBit Trace AGBT interface operating at their maximum frequency Its small and compact hardware size allows for connecting to a target mic...

Страница 5: ...Package content The DAP over CAN Physical Layer Converter is delivered with the following components DAP over CAN Physical Layer Converter USB C cable User Manual Ordering code IEA DXCPL ...

Страница 6: ...GND 3 4 NC GND 5 6 RXD O NC 7 8 NC GND 9 10 NC DAP connector pinout Signal direction definition O Output from the Active Probe to the target microcontroller I Input to the Active Probe from the target microcontroller B DB9 connector Pinout valid on the DB9 connector side Pin Signal 1 Not connected 2 CAN_L 3 CAN GND 4 NC 5 SHIELD 6 NC 7 CAN_H 8 NC 9 NC DB9 connector pinout ...

Страница 7: ...tatus of the hardware as follows Green Powered on Red Power supply issue e g burnt fuse D USB C cable which is connected to the PC USB port CAN 120 Ohm terminating resistor is not implemented on the DAP over CAN Physical Layer Converter ...

Страница 8: ...over CAN Physical Layer Converter in winIDEA 1 Open Hardware menu CPU Options 2 Navigate to the SoC page 3 Select DXCPL from the Debug channel Mode drop down 4 Confirm and establish the debug connection Refer to isystem com connect for more information on how to connect and configure the hardware ...

Страница 9: ...FNET 500 5 0m FNet Cable Active Probe BB FNETMICRO 100 1 0m FNet Micro Cable Active Probe Please refer to the iC5700 BlueBox for all current iC5700 Accessories The functionality of the DAP over CAN Physical Layer Converter can be extended through the use of various accessories Ordering Code Description IC57040 CAN DB9 1m CAN cable DB9 plug IC57040 CAN PIN CAN cable pin wires IC57040 CAN JACK CAN c...

Страница 10: ...User Notes This page is intentionally left blank ...

Страница 11: ...User Notes This page is intentionally left blank ...

Страница 12: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...