3
When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.
26-pin 2.54 mm NXP ColdFire Debug Adapter features resettable fuses on pins 2, 4, 7, 8, 9, 10,
24 and 26. These protect debug signals against overcurrent and cycle back to a conductive
state after the excessive current fades away. Signals on pins 1, 12-19 and 24 are protected via
47 ohm serial resistors.
The debug adapter connects to the target via a 26-pin 2.54 mm connector, for example
Yamaichi FAS-26-17. A target should feature a matching part, for example WÜRTH ELEKTRONIK
61202621621.
Содержание IC50130
Страница 1: ...Legacy Debug Adapters V1 1 User Manual ...