background image

Setting Up Summary 

(1)  Startup and network association 

Note:  when  successfully  joined,  we  strongly  suggest  you  to  allow  1  minute  performing  self 

calibration  on  the  meter  before  it  is  ready  to  take  load.  This  is  particular  important  for  correct 

reading.

 

(2)  Pair the device with other device where applicable (i.e. bind it with a ZigBee switch 

for wireless control). 

(3)  When it is bind with a controlling device it is then ready to be used. 
(4)  Power/current consumption monitoring 

S

tep 1. 

Startup and Network Association

 

Setting up the SGZ805A and network

 

 

 

 
 

 

 

To allow SGZ805A to function, it must first join to a ZigBee network. When it is given 

powered it will automatically start searching for an existed network. So before you give 

power to SGZ805A make sure it is within the wireless coverage distance (~150 meters or 

less) and make sure 

first 

you have the 

permit-join feature enabled 

either on a 

coordinator or a router device in the network so that SGZ805A will join to the network 

through it; then give power to SGZ805A and it will join into the network by itself. 

*

On how to enable permit-join please refer to the router or coordinator device user manual 

 

 

Operation:

 

Step 1: Make sure you have open up permit-join function (valid for 60 seconds) of a 
coordinator or a router 
Step 2: Now wire the AC cable of SGZ805A to the AC source to power it up. SGZ805A device 
will start to search for the network within reach. 
Step 3: When the device found the network, the LED indicator on the SGZ805A will 
flash. A non-flashing solid light indicates successful join otherwise the indicator stays dark. 

 

How to wire the device

 

Please go to 

Power Cable Installation 

section. 

Содержание ZigBee SGZ805A

Страница 1: ...Sysmart i ZigBeeTM Power Switch w Energy Consumption Monitoring User Manual Power Switch Unit Model SGZ805A Energy Consumption Monitoring Series For Home Automation Network ...

Страница 2: ...N N L IN L OUT Switch Key Binding Key External Switch Power Switch Unit SGZ805A Figure 1 SGZ805A ...

Страница 3: ...nagement system application software to view power or current consumption What is ZigBee ZigBee is a short range wireless transmission technology which defined for a minimum complexity low power consumption low data rate cost effective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousand...

Страница 4: ...power to SGZ805A make sure it is within the wireless coverage distance 150 meters or less and make sure first you have the permit join feature enabled either on a coordinator or a router device in the network so that SGZ805A will join to the network through it then give power to SGZ805A and it will join into the network by itself On how to enable permit join please refer to the router or coordinat...

Страница 5: ...ccording to the instructions of that device When pairing is successful the LED indicator on SGZ805A flashes 5 times then turn solid lit otherwise it flashes 10 times indicating pairing unsuccessful Clear pairing setting You may remove the pairing between the two or more devices Unbinding procedure is exactly the same as binding operation When you repeat the binding operation the two devices will r...

Страница 6: ...n reading to ISysmart s application or to any 3rd party in home display Power drawn overtime is measured Current unit mA Voltage unit V Power unit W and Energy unit Wh Permit other device to join SGZ805A is featured to be a router in the network It permits join other devices to the network By default the router device SGZ805A does not allow permit to join function in a normal operation to protect ...

Страница 7: ...3rd second and once on the 10th second then the indicator will start flash quickly for 20 seconds You may release the key Now the device has restored to the factory setting 2 Within this 20 seconds press the binding key again to force device reboot Soon the device will enter network search mode to attempt to join to a network Refer to Network Association section of the manual Overload Protection W...

Страница 8: ... binding key more than 15s 4 timely flashes When the LED flash becomes quickly release the press again to reboot the device Permit Join Short press binding key once Flashes 60 times in 60 seconds Device Pairing Hold press binding key 3s Flash once Flash 5 times successful Flashes quickly 10 times unsuccessful ...

Страница 9: ... wires are actually one So you may see it as depicted in Figure 2 We provide an extra neutral wire for your installation convenience Load wiring schematic is shown in Figure 3 and 4 Figure 1 Figure 2 AC input plug Or wiring AC input plug Or wiring or Figure 3 Load fan lights Figure 4 Load fan lights L out L in N_1 N_2 L out L in N_1 N_2 ...

Страница 10: ...ernal Switch Other than being a wireless power switch SGZ805A is given external switch connectors toenable conventional switch to be attached Choose a normally open switch to connect You may use any range of current rating of the switch as the switch cable does not run load current but switch signal change ...

Страница 11: ...0005 On Off 0x0006 Commission 0x0015 Meter 0x0702 Attributes of the Basic Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x0B O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 0x2D O 0x0003 HWVersion Unsigned 8 bit integer...

Страница 12: ... O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x01 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M ...

Страница 13: ...e other routers do This result implied that SGZ805A is within the network and receives command from thenetwork no problem How to enable permit join please refer to any ZigBee router device for such feature Test 3 If test 1 and 2 items are found working then what was left is device pairing between SGZ805A and the control device Please refer to Step 2 in the beginning of the manual Please keep in mi...

Страница 14: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...

Страница 15: ...rt is not responsible for data or revenue loss or any indirect additional loss that may arise from special cases or any sudden obligations This documentation is provided according to the product at the time of purchase ISysmart do not inherent any responsibility and promise or guarantee of the reliability of thedocument contents this applies but not limited to market piloting or real use case purp...