background image

10 

 

0x0010 

LocationDescription 

Character 

string 

0 – 16 

bytes 

Read/write 

16 

 

Afterwards 

0x20 

0x0011 

PhysicalEnvironment 

8-bit 

Enumeration 

0x00 – 

0xff 

Read/write 

0x00 

0x0012 

DeviceEnabled 

Boolean 

0x00 – 

0x01 

Read/write 

0x01 

Содержание SGZB02I

Страница 1: ...Sysmart i ZigBeeTM Wireless Panic Button User Manual Wireless Panic Button Model SGZB02I ...

Страница 2: ...gram 6 5 Setting up SGZB02I 7 5 1 Turn On SGZB02I 7 5 2 Join the ZigBee Network 7 5 3 Enroll in the ZigBee Security System 7 5 4 Sleeping Mode 8 5 5 HeartBeat Technique 8 5 6 Battery 8 5 7 Restore to Factory Setting 8 6 Home Automation Clusters for SGZB02I 9 7 Important Maintenance Instructions 11 ...

Страница 3: ...nd commands to a siren device to trigger an alarm The Warning Device will generate alarm sound or lighting alert for immediate help What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low power co...

Страница 4: ...4 2 Product Appearance ...

Страница 5: ... compliant Utilizes 2 4GHz ISM band up to 16 channels Power supply 2 x AAA batteries Operating consumption 40mA Standby consumption 1uA Up to 210 meters wireless transmission range in non obstacle space Easy installation and configuration ...

Страница 6: ...6 4 Installation Diagram ...

Страница 7: ...r manual of the coordinator or the router to enable the permit join feature Step2 Turn on SGZB02I It will start to search and join the network Step3 The indicator will flash green once when it finds out a network to join Step4 The indicator will flash green 5 times after it is joined successfully Otherwise the indicator will not flash NOTE After joining the network SGZB02I will try to enroll in th...

Страница 8: ...nted power consumption we recommend that users manually power off the device 5 5 HeartBeat Technique In a security system it is important that Zone devices report the conditions to the central security unit the CIE device To meet this need ISysmart came up with a technique called HeartBeat Right after SGZB02I enrolls to a security system it sends a HeartBeat signal to the CIE device Afterward it w...

Страница 9: ...3 IAS zone 0x0500 commissioning 0x0015 This lists the attributes of the basic information Attributes of the Basic Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only O 0x0003 HW...

Страница 10: ... LocationDescription Character string 0 16 bytes Read write 16 Afterwards 0x20 O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M ...

Страница 11: ...tures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do not paint the device Paint would c...