background image

1. 

Short press the binding key once (less than 3 seconds)

2.  The  permit  join  is  now  enabled  for  60  seconds  and  the  indicator  light  will  flash  60 

times. 

3.  SGZA10 waits the new device to join in automatically. Please note that the maximum 

waiting time to join is 60 seconds. Repeat the process if you missed the 60 seconds 
period. Within the 60 seconds, short press the binding key when you want to disable 
the permit-join finction. 

 
 
 
 

 

Restore to factory setting

 

SGZA10 is capable of storing and saving includes network routing information. If you wish 
to remove SGZA10 from the network and join to a new network, you would need to clear 
the setting by simply reset the device to restore to the factory setting. 

 

Operation:

 

Step 1. 

First remove the power from the device 

 

Step  2. 

Hold  on  to  the  binding key. While doing  so,  power  up  the  device  again  to  give 

power,  until  the 

indicator  light  flashes  quickly 

then  release  the  key.  If  you  want  the 

keeper to be a gas keeper then go to Step 4 instead of 3 because 

by default SGZA10 is a 

gas keeper

. But to program the keeper as water keeper then go to Step 3. 

 

Step  3.  To  configure  SGZA10  as  water  keeper, 

while the indicator is flashing quickly 

from Step 2, 

short  press  the  binding  key  once

.  This  will  configure  it  to  become  a 

water keeper. Now go to Step 4. 

(To make the device as a gas keeper, you should skip this step and go to step 5) 

 

Step 4. 

Now the device is restored to the factory setting. Now power cycles the device to 

put the device into network search mode. 

(Note: by default SGZA10 is a gas keeper) 

Содержание SGZA10

Страница 1: ...Sysmart i ZigBeeTM Gas Water Keeper User Manual Gas or Water Keeper Model SGZA10 ...

Страница 2: ...ED Binding key Manual lever releaser Lever Power receptor Installation holder Gas Water Keeper SGZA10 Other ISysmart related devices Switch controller Multiple Scene controller SGZ503 Smoke detector SGZA01A B C D ...

Страница 3: ...A10 s operating pressure is 7 kgf Valve rotation angle is 90 What is ZigBee ZigBee is a short range wireless transmission technology which defined for a minimum complexity low power consumption low data rate cost effective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE806 15 4 standard the mutual co ordination between thousands of sensors ...

Страница 4: ...If it is a water keeper it will receive on or off instruction from a remote controller by the user Step 2 Power up the device and network association To allow SGZA10 to function it must first join to a ZigBee network either through a coordinator or a router device When it is given power it will automatically start searching for an existed network So before you give power to SGZA10 make sure it is ...

Страница 5: ...rollable device which receive command signal from a zone device i e upon receive a smoke alarm it changes the position of the leaver So pair SGZA10with a smoke gas detector As a water keeper the device can be controlled wirelessly from a paired remote controller So pair SGZA10 with an On Off remote controller The pairing operation is the same for both types except for the types of device to pair w...

Страница 6: ...0 is configured as a gas keeper On the fire event the paired device sends command to gas keeper and brings the lever to down position Manually release the lever lock button by pushing it inwards to release the lever so you can move the lever either up or down NOTE When the Manual Lever Releaser Button lever lock button keeps inwards as the figure below please slightly move the lever to release the...

Страница 7: ...ice to restore to the factory setting Operation Step 1 First remove the power from the device Step 2 Hold on to the binding key While doing so power up the device again to give power until the indicator light flashes quickly then release the key If you want the keeper to be a gas keeper then go to Step 4 instead of 3 because by default SGZA10 is a gaskeeper But to program the keeper as water keepe...

Страница 8: ... Commissiong 0x0015 Attributes of the Basic Device Information attribute set Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0X03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0X0E O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 0X2E O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xf...

Страница 9: ... 16 bytes Read only 20130122 O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0X04 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O ...

Страница 10: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...

Отзывы: