background image

16 

 

FCC Statement: 

 

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation. 

 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital  device, 
pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection 
against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that 
interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and  on,  the  user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the  following 
measures: 

 

—Reorient or relocate the receiving antenna. 

 

—Increase the separation between the equipment and receiver. 

 

—Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is 
connected. 

 

—Consult the dealer or an experienced radio/TV technician for help. 

 

Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party  responsible  for 
compliance could void the user's authority to operate the equipment. 

 
 
 
 

 

Содержание SGZ308

Страница 1: ...iSysmart ZigBeeTM ZigBee Wearable Presence Tag with Emergency Button User Manual ZigBee Wearable Presence Tag with Emergency Button Model SGZ308 ...

Страница 2: ...rk 6 5 3 Enroll in the ZigBee Security System 6 5 4 Sleeping Mode 7 5 5 Wake up SGZ308 7 5 6 Panic Button 7 5 7 Presence Tag 8 5 8 HeartBeat Technique 9 5 9 Battery 9 5 10 Restore to Factory Setting 9 5 11 Offline activation 9 6 Home Automation Clusters for SGZ308 10 7 ISysmart App Control Interface 12 8 Related ISysmart Devices 14 9 Important Maintenance Instructions 14 ...

Страница 3: ... SGZ308 will send the alarm message to the command center The Warning Device will send out alarm sound or lighting alert for immediate help What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low ...

Страница 4: ...3 Indicator Red Green Panic Button 2 Product Appearance ...

Страница 5: ...tilizes 2 4GHz ISM band up to 16 channels Power supply 1 x CR2450 3 0V battery Operating consumption Tx 33mA Rx 28mA Standby consumption 1 3uA Wireless transmission is up to 200 meters linear distance in open field Easy installation and configuration ...

Страница 6: ...5 4 Installation SGZ308 is waterproof ...

Страница 7: ...s and hold button for three seconds to search a network to join Step4 The indicator will flash green 5 times after it is joined successfully Otherwise the indicator will not flash Step5 When SGZ308 can not join a network in 3 minutes it will go into off mode To ask for joining Network again press and hole button for 3 seconds After joining a network SGZ308 would try to enroll in the ZigBee securit...

Страница 8: ... following steps Step1 Press and hold the Panic Button for 3 seconds Release the button when the indicator flashes red once Step2 The indicator flashes green 5 times when SGZ308 is online Step3 SGZ308 will broadcast the device data to the ZigBee network SGZ308 would be in active status for 2 minutes for communication 5 6 Panic Button SGZ308 s Zone Type Key Fob ID 0x0115 The value of Alarm2 is 1 wh...

Страница 9: ...ouble 1 Trouble Failure 0 OK 7 AC mains 1 AC Mains fault 0 AC Mains OK 8 15 Reserved Values of the ExtendedStatus payload ExtendedStatus Attribute Bit Number Meaning Values 0 6 ZoneID 7 ZoneStatusChange Or Heartbeat 1 HeartBeat 0 ZoneStatusChange 5 7 Presence Tag SGZ308 works as a presence tag It is an ideal product to detect one s presence within out of the network coverage for safety purpose SGZ...

Страница 10: ... low power report to the ZigBee network The related data Power configuration cluster ID 0x0001 Battery voltage attribute ID 0x0020 5 10 Restore to Factory Setting To restore it to factory setting please follow the steps Step1 Press and hold the Panic Button or 15 seconds Step2 Release the button after the indicator shows fast red flashes Step3 After 10 red flashes it will go into turn off mode The...

Страница 11: ...x0001 Identify 0x0003 IAS zone 0x0500 Commissioning 0x0015 Poll Control 0x0020 Diagnostics 0x0B05 This lists the attributes of the basic information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x28 O 0x0002 StackVersion Unsigned 8 bit integer 0x0...

Страница 12: ...11 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x03 M ...

Страница 13: ...12 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M ...

Страница 14: ...d device to device list of SGZ308 in ISysmart App and the device information will show up in the management interface as below IAS Zone device The added device EP01 is a Panic Button device type Choose it to enter control interface as below ...

Страница 15: ... the button shortly to carry out the emergency alarm Through the following interface of APP setting you can set the Alarm sound after the emergency alarm Choose about device to check device information as below ...

Страница 16: ... device in extremely hot temperatures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do no...

Страница 17: ...ance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Отзывы: