Top of Form Calibration
1. Press
Start
.
2. You will now see a number for sensor output.
3. Insert paper until the sensor is above the white space.
4. Manually adjust the gain by pressing either
Increase Gain
or
Decrease Gain
until the sensor is below 45
for white space.
5. Insert the paper in more until the sensor is above the I-mark. Manually adjust the gain until the sensor
detects 180 or higher for the I-mark.
6. Press
Stop and Save
.
Manual calibration
Calibrate TOF lets you calibrate the Top of Form. You can adjust the gain by pressing the
Increase Gain
or
Decrease Gain
buttons. The target numbers are as follows:
Sensor Detects
Sensor Output Target
Whitespace
Less than 45
Top of Form
Greater than 180
Содержание iTerra IJ875
Страница 16: ...16 Select a sharing option h Press Next STEP 15 Enter a location and a comment h Press Next STEP 16 ...
Страница 18: ...18 Go to the Windows Start button h Control Panel STEP 2 ...
Страница 19: ...19 Select Printer under Hardware and Sound STEP 3 Select Add a printer STEP 4 ...
Страница 23: ...23 Press Next STEP 11 Type a name for the printer h Press Next STEP 12 ...
Страница 26: ...26 STEP 1 Left click the Start button h Right click on the Computer tab h Left click on the Manage item ...
Страница 28: ...28 STEP 3 Right click on the Apple USB Ethernet Adapter and left click on the Update Driver Software STEP 4 ...
Страница 30: ...30 Click Next STEP 7 Click Have Disk STEP 8 ...
Страница 34: ...34 Select Don t search I will choose the driver to install STEP 3 Click the Have Disk button ...
Страница 37: ...37 Once that the driver is installed click Finish ...
Страница 44: ...44 Web Interface Default Username Admin Default Password Admin ...
Страница 45: ...45 ...
Страница 46: ...46 ...
Страница 47: ...47 ...