6. Maintenance / Care / Disposal

The product is maintenance-free. It is sufficient from time to time to 
remove any dust deposits. This may only be done in a power-free 
state.

Disposal (European Union)
Do not dispose of product in household waste! Products with this 
symbol

7. Storage

The product must be stored in a dry place, protected from dirt and 
mechanical stress. After damp or dirty storage, the product may only 
be operated after a condition check by an authorised electrician. 

8. Assembly

(Only by certified electrician!)
Mount the product only when it is in a power-free state!
Switch off the power supply, check that there is no voltage, secure 
against being switched on again!

Only use suitable equipment that meets the electrical requirements 
of the device!
Check that there are no loose parts in the product. If this is the case 
and the presence of such parts is not explicitly described, do not 
install or commission the product. 
Only use suitable cables and fixing screws. 

Assembly site

• The product is intended for installation in luminaires or profiles.

Assembly steps
(Read completely before assembly!) 

• Mount the device in a way that the light sensor looks into the area 

to be measured. The sensor works with the reflection measure-
ment method, so direct light irradiation by the luminaire must be 
avoided.

• Make the electrical connections according to the wiring diagram. 
• Only after a complete connection and a visual test by a qualified 

electrician, the system may be put under voltage.

Seebacher GmbH

Marktstrasse 57
83646 Bad Tölz
GERMANY

Phone: +49 (0) 80 41 / 77 77 6 
Fax: +49 (0) 80 41 / 77 77 2

www.seebacher.de
[email protected]

5. Service address

4. Declaration of Conformity

The valid declaration of conformity for the module can be requested 
from us free of charge by stating type and article no. as follows:
By phone: 

+49(0)8041/77776

By fax: 

+49(0)8041/77772

By mail: 

[email protected]

3. Warranty

We provide warranty within the framework of the statutory provisi-
ons. These are limited to the intended use of the module and refer 
to the repair or replacement of the ISYGLT module. Please send the 
device with an attached error description to our company address 
given below. 

must be disposed of according to the EU directive WEEE 2012/19/
EU on waste electrical and electronic equipment at the local collec-
tion points for waste electrical and electronic equipment!

Содержание LS-05-HF-WH

Страница 1: ...acher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 LS 05 HF WH Article no 80085064 Digital Light Sensor with integrated HF Motion Sensor Technica...

Страница 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Страница 3: ...liability for printing errors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may on...

Страница 4: ...r installation in luminaires or profiles Assembly steps Read completely before assembly Mount the device in a way that the light sensor looks into the area to be measured The sensor works with the ref...

Страница 5: ...on of movement towards or away from the sensor can also be evaluated for control functions Connections miniature plug Molex 51021 0400 4 pole cable to RJ10 incl terminal adapter Design miniature plast...

Страница 6: ...rogramDesigner Display and buttons at the sensor State Meaning Function LED red slow flashing Sensor has no address fast flashing Sensor is in programming mode Off Sensor has a BUS address individual...

Страница 7: ...ted as a module Additionally a virtual module ISYGLT_ADR is required To set the BUS address the desired address must be entered in the register Parameter Now the sensor to be addressed must be put int...

Страница 8: ...6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 Misprints and technical changes reserved 11 Wiring diagram View 24V 24V 0V 0V BUS A BUS A BUS B BUS B 001 BUS address Light HF...

Отзывы: