IC-M29
Page 27 / 58
Rev 1.0
7.3.23 Optical Black Clamp Level
Type
Command
Response
Description
Get
“gcl<\r>”
“<0~700><\r><\n>”
0 = Min.Black Clamp Level
700 = Max.Black Clamp Level
Set
“scl <0~700><\r>”
“OK<\r><\n>”
7.3.24 Optical Black Clamp Level Offset
Type
Command
Response
Description
Set
“sco <0|1|2|3> <0 ~ 700><\r>”
“OK<\r><\n>”
<0|1|2|3>
0 = Channel A
1 = Channel B
2 = Channel C
3 = Channel D
<0 ~ 700>
0 = Min.
700 = Max.
7.3.25 Config Initialization
Type
Command
Response
Description
Get
“gci<\r>”
“<0|1|2><\r><\n>”
0 = Factory Default
1 = User 1
2 = User 2
Set
“sci <0|1|2><\r>”
“OK<\r><\n>”
7.3.26 Load & Save Config
Type
Command
Response
Description
Load
“lcf <0|1|2><\r>”
“OK<\r><\n>”
0 = Factory Default
1 = User 1
2 = User 2
Save
“sct <1|2><\r>”
“OK<\r><\n>”
1 = User 1
2 = User 2
7.3.27 Current Temperature
Type
Command
Response
Description
Get
“gct<\r>”
“<s1> <s2><\r><\n>”
s1 = Fahrenheit's
temperature scale
s2 = Celsius
temperature scale
All manuals and user guides at all-guides.com