III. Engine Servicing Procedures
U
L-Series Diesel 25
Injector Pop-off Test
WARNING: FLUID FROM THE NOZZLE TESTER WILL SPRAY OUT UNDER
GREAT PRESSURE. IT CAN EASILY PUNCTURE A PERSON’S SKIN. KEEP
YOUR HANDS AWAY FROM THE NOZZLE TESTER AT ALL TIMES.
Use the following procedure to check
nozzle opening pressure, spray pattern,
chatter and leakage:
Mount the nozzle and holder assembly to
the gauge (J28829) and bleed the system of
air.
Open the pressure gauge valve and pump
the lever at a rate of one stroke per second.
Then check the opening pressure. When the
pressure gauge pointer decreases rapidly,
read pop-off value. (Refer to engine’s
specification sheet for values. An Indirect
Injection will have lower readings than a
Direct Injection engine.)
IMPORTANT! If the nozzle opening
pressure is not steady or cannot be
checked the trouble is with the nozzle
assembling procedure.
If the nozzle “pop-off” pressure does not meet factory pressures, disassemble the nozzle
and make a shim adjustment. The following size shims are available through AIPDN.
Shim Part Number
Shim Size
mm
894176-9620
0.10
894176-9630
0.20
894176-9640
0.30
894176-9650
0.40
894176-9660
0.50
894176-9670
0.52
894176-9680
0.54
894176-9690
0.56
894176-9700
0.58
894176-9710
0.80
Содержание 3LA
Страница 42: ...VII Appendix Miscellaneous Service Information U L Series Diesel 41 NOZZLE...
Страница 43: ...VII Appendix Miscellaneous Service Information U L Series Diesel 42...
Страница 44: ...VII Appendix Miscellaneous Service Information U L Series Diesel 43...
Страница 45: ...VII Appendix Miscellaneous Service Information U L Series Diesel 44...