       Installation guide 

Local Control Network  -  building controls in perfection

8

LCN-ULT

®

For safety reasons, this function can only be carried out directly on each single LCN-
ULT. 
Transferring  the  command  „ERASE ALL“  to  other    LCN-ULT´s  in  the  LCN  Bus,  is  not 
possible!

Building installation with several LCN-ULT´s 

 (group formation, ”commission”)

When many LCN-ULT´s are being operated within one installation, the correct master 
card from each associated transponder reader must always be used for programming. 
To make this management more simpler, the following possibility has been created, to 
combine many LCN-ULT´s into a “group” or “ commission”. 
This is possible with an order of over 5 LCN-ULT´s! 
When ordering you must state, how many transponder readers and how many master 
cards that have to be combined. LCN-ULT´s will then be delivered, so that all the LCN-
ULT´s can be programmed using the same master card.  Even the amount of  master 
cards is optional. Reordering for such a commission is possible at any time.  No groups 
or commissions can be later formated for  LCN-ULT´s that have been already delivered. 

LED blue/red

The colours of the Duo-LED´s can be toggled with a command and controlled in different 
brightnesses (for max. brightness, stronger power supply required). To do this, use the 
command  “LED control / LCN-ULT”  in the LCN-PRO version 3.5 or later.

Содержание LCN-ULT

Страница 1: ...ontrol systems time recording systems and alarm systems mechatronical lock cylinders and locks Over LCN allowance can be granted for example for access permission for electronical locked doors or othe...

Страница 2: ...k building controls in perfection 2 Installation white yellow green free power supply LCN IV transponder reader LCN ULT brown to the I port of an LCN module adapter for the I port connection cable app...

Страница 3: ...e Minimum distance between two LCN ULT transponder readers to avoid them from interfering with each other a possible distance of 75cm should be kept between each LCN ULT Connection LCN ULT can be conn...

Страница 4: ...s such influences and reduces the transmitting power automatically When a distinctive range reduction occurs please try the function with the reading head away form its fixing point should the require...

Страница 5: ...tly again Then go back into the learn mode again Preparing for operation learning new transponder types with several LCN ULT s If there are there more than one LCN ULT in the building it is possible t...

Страница 6: ...ed base The LCN ULT cannot read out these keys Should a new generation of transponder chips be produced that the LCN ULT doesn t know today the transponder reader can become a new firmware update by l...

Страница 7: ...ransponder reader for longer than 15 seconds When the master card is recognised the LED will flash in blue After about 5 seconds it will flash slowly in red After a further 10 seconds the slow flashin...

Страница 8: ...reated to combine many LCN ULT s into a group or commission This is possible with an order of over 5 LCN ULT s When ordering you must state how many transponder readers and how many master cards that...

Страница 9: ...parts have to be sent together for repairs or replacements When a master card is lost a replacement delivery is possible Unknown transponders firmware updates Should there be an unknown transponder o...

Страница 10: ...one Function Feedback LED Action with mit car key Installation guide Local Control Network building controls in perfection 10 LCN ULT new key type transponder type learning with an LCN ULT with severa...

Страница 11: ...11 Installation guide Local Control Network building controls in perfection LCN ULT Dimensions of the reader...

Страница 12: ...s can be obtained from the technical hotline 30 C to 70 C IP65 68mm flush mounted box 80mm x 80mm 11 7mm 27 7mm white optional silver ASA water and UV resistant 2 fine wire 4x 0 14mm wire ends tinned...