3V DC
7,5µA, 14,3mA for each 14ms
lithium-cells 2450 / 4-5 years. When used permanently in 
the LF-field approx. 2 years
2/Hit functions with control LED

125kHz (globe formed detection range)
3D
depending on the settings of the  LCN-ATW

up to 50m in an open environment

IP65
-20°C to +70°C
47mm x 63mm x 17mm
black/PA6 GF10 GK20/29g
eyelet for keys, 15 x 5mm, oval 

868MHz (free of charge, usable ISM Band)

connection

operating voltage:
operating current:
battery/life expectancy:

inputs/push-button functions

LF-/HF-technic

LF (low frequency-magnet field):
reception characteristic:
range (LF, passive transfer):
HF (high frequency-magnet field):

Installation

protection art:
operating temperature:
dimensions (W x H x D):
colour/material/weight: 
fixing:

HF

range (HF, active transfer)

Technical data LCN-AT2

Technical  information and images are non binding. Changes are reserved.

Technical hotline: +49 5066 998844 or www.LCN.de