Programming the Central Softener System
(1)
Button Configuration
•
MENU: This function is used to enter the basic setup information required at the time of
installation.
•
SET/REGEN: This function is used to initiate an immediate or delayed manual regeneration.
•
DOWN/UP: These buttons are used to increase or decrease the value of the settings while in
programming mode.
(2)
Key Functions
"MENU"
•
Press and hold for 3 seconds to unlock the device while in standby mode.
•
Press and hold for 3 seconds in the unlocked state to enter the user menu settings, which
include items such as regeneration mode, time, date, etc.
•
In the user menu display, press this button to exit the menu display immediately.
"SET/REGEN"
•
While in the unlocked state, press and hold for 3 seconds to enter the manual regeneration
mode. You can choose vacation mode, immediate regeneration,or full-cycle immediate
regeneration.Choose vacation mode and input estimated holiday days.The valve will
regenerate in smart clean mode (see p.17) when no water is used during thesedays; if thereis
water used during the days, the vacation mode will automatically turn off.
•
Delayed regeneration means that the system will start a regeneration at the next
regeneration time regardless of the remaining regeneration days or water consumption.Press
and release the button to set a delayed regeneration that will occur at the regenerationtime.
•
Immediate regeneration means that the system immediately starts a regeneration.