8. ROLLER BLIND ADJUSTMENT AND TESTING 

 

ADJUSTING THE MOTOR SWITCH LIMITS 

NOTE: 

Wiring, installation and maintenance may only be carried out by qualified personnel, authorised and competent for 

said  operations.  The  roller  blind  can  be  supplied  either  with  a  standard  motor,  or  with  an  RTS  motor  with  an  integrated 

remote control receiver: 

 

STANDARD MOTOR:  

The motor cable has 4 conductors: 

 

blue = neutral conductor, 

 

brown = opening/closing, 

 

black = opening/closing, 

 

yellow-green = ground. 

 

When  connecting  the  conductors  to  a  terminal  block  inside  the  main  switch,  check  which  brown  and  black  conductor 

corresponds to opening and which to closing of the roller blind (this depends on which side of the drum the motor is to be 

installed). 

 

RTS MOTOR: 

 

The motor cable has 3 conductors: 

 

blue = phase/neutral conductor, 

 

brown = phase/neutral conductor, 

 

yellow-green = ground. 

 

Motor switching can be installed in two different ways: either using a switch, or using a programming set (on request). 

The 

instructions for programming and adjustment of limit switches are shown in a separate manual.

 

To set up the limit switch, first turn on the motor to roll the roller blind down and set the required maximum down position, 

then run the motor in opposite direction to draw the roller blind up. 

 

Prior  to  final  connection  and  operation,  check  if  the  system  works  properly.  Operate  the  roller  blind  for  at  least  two 

consecutive cycles and check the function of thermal disconnection after 4 minutes of continuous operation. In case of any 

problems, study Chapter 8. 

 

NOTE: There is a risk of compression in case a  hand is trapped between the fabric and the upper box  when the 

roller  blind  is  drawn  up.  Before  operating  the  roller  blind,  move  your  hands  outside  of  the  movement  range  to 

prevent compression. Vibrations or excessive noise indicate damage or faulty installation of the roller blind. 

Содержание ZIP ECO

Страница 1: ...n front of an opening As a rule indicate the width of the opening which is to be shaded in the order form 2 x 40 mm Dimensions outside the stipulated limits must be consulted with the manufacturer H h...

Страница 2: ...enting the penetration of water and protecting all electrical components Power supply Electric power mains 230 v ac Frequency 50 60 hz Voltage fluctuation tolerance 10 Interference level below 70 db O...

Страница 3: ...scaffolds balconies etc or at elevated bridges If it is impossible to use such facilities suitable individual protection means must be used The scaffolds platforms and elevated working areas must be e...

Страница 4: ...e using portable drills and screwdrivers 2 Roller blind installation to a frame or wall 3 Connection to power mains 4 Adjustment of end stops motor limit switches etc and testing of the roller blind P...

Страница 5: ...zipper moves A Aluminium guide rail B Plastic guide rail 1 Insert the guide rails in the side piece mandrel check if height of the guide rails is the same 2 Cut the plastic guide rail to size with the...

Страница 6: ...s together with the control unit in all situations where there is more than one device to control the same roller blind The control unit will store the provided impulse for approx 3 minutes or until r...

Страница 7: ...brown phase neutral conductor yellow green ground Motor switching can be installed in two different ways either using a switch or using a programming set on request The instructions for programming an...

Страница 8: ...eed assistance contact your dealer and ask for original spare parts DISASSEMBLY DISPOSAL As regards Directive 2002 95 EC RoHS on the use of lead chrome cadmium and other substances hazardous to enviro...

Страница 9: ...tape directly onto the winding drum on the side opposite to where the fabric is moving Repeat applying further adhesive tape layers until the defect is completely removed Drum cover displacement If th...

Страница 10: ...ng operation Otherwise contact technical support Increased noise Motor failure Disconnect the motor test it and replace if necessary Motor blocks after a long period of service The motor is in the the...

Отзывы: