MEASUREMENT AND ASSEMBLY MANUAL
Validity of the manual: 1. 8. 2016
1
EXTERIOR BLINDS TITAN 90
1. MEASUREMENT
Measure the width (SZ) and height (VZ) of the blind.
Measure the width (SZ) of the blind at least at 3 points, on the top, in the middle and on the bottom.
Use the lowest measured value for ordering and production of the blind.
ATTENTION! Produced width (SV) of the blind TITAN is always shorter compared to measured one according to
chosen assembly option. See: Assembly options.
Measure the height of the blind (VZ) at 3 points as well, on both sides of lining and in the middle. Use the lowest
measured value for ordering and production of the blind.
ATTENTION! Produced height of the blind TITAN (VV) is always 20 mm shorter compared to the measured one
(VZ). The reason is ensuring manipulation space for assembly process and space for fixing brackets for front
cover of the blind.
Note:
Real width of produced blind (SV) is always shorter compared to the one in order form. Width difference comes from the
chosen assembly option. For assembly onto lining it is obligatory to use 2 mm distance pads (D). The pads help to adjust
vertical level of guiding rails. Real height of produced blind (VV) is always 20 mm shorter than the one in order form. The
reason is ensuring manipulation space for assembly process and space for fixing brackets for front cover of the blind.