72
73
INTERIOR BLINDS
72
73
motor control
Motor control - position 50
Motor controls serve for pulling the blind up and down and setting the slat.
Motor controls allow selecting the control by the sun/wind sensor, remote control, or switch. It is possible to control several blinds at once
depending on their dimensions. In this case, the motor is located in one blind in the group.
Types of motors
Item name
Business name
Drawing number
Motor GJ5603 - 3Nm - complete set
P 093/1
6-006880-xxxx
Clip for motor cable
P 202
6-006483-0000
Motor J002 left (1,5Nm)
6-011272-xxxx
Fastening set for Somfy motor J002
6-009798-0000
Motor J406 6/24 WT (6Nm)
P 073/6J
6-002594-xxxx
Motor J418 18/24 IO (18Nm)
6-011389-xxxx
Metal holder for Somfy HTM cable
6-011384-0000
Motor J410 RTS 10/24 WT (10 Nm)
6-002593-xxxx
Motor J506 6/26 HTM (6Nm)
P 073/6JHTM
6-010361-xxxx
Female STAK3 - Hirschmann
6-001658-0000
Clip for motor cable
P 202
6-006483-0000
Motor ELERO JA 06 SOFT, 6Nm
P 096/6
6-008179-xxxx
Bearing 70-90 NHK, 12mm 4hr.
6-011804-0000
Bearing 50-65 NHK, 12mm 4hr.
6-011810-0000
Motor ELERO JA 10 NHK-A,10Nm
6-011801-0010
Thinwall closed profile 12x12x1,5 A2
6-011802-1215
Hexagonal gearing 12x12mm,NHK
6-011803-0000
Holding bracket for gearing GEIGER
6-011805-0000
Adapter for flat rod 14 mm - motors GEIGER
6-001624-0004
Pad M5
6-002350-0000
Screw M5x8
6-002353-0000
Important Instructions:
•
The electric equipment can be assembled only by qualifi ed persons.
•
Never connect more than one motor to one switch. One switch can control more drives only in the case of group control.
Note: See the manuals of Somfy, Geiger and Elero companies for detailed wiring diagrams.
Motor Wiring Diagram
RTS Motor Wiring Diagram
Parameter
motor Somfy
motor Geiger
Torque
6 - 18 Nm
3 - 20 Nm
Power Input
90 - 210 W
90 - 190 W
Current Consumption
0,41 - 0,7 A
0,4 - 0,85 A
Nominal Voltage
230 V / 50 Hz
230 V / 50 Hz
RPM
24 ot./min.
26 ot./min.
End Switch Capacity
73
80
Motor Protection Class
IP54
IP54
Maximum Operation Time
cca 6 min.
cca 6 min.
Weight
1,35 - 2,41 kg
1,5 - 2,2
Motor control
1 - Neutral wire (N)
2 - Phase wire (L)
3 - Not connected
4 - Ground wire (PE)
1 - Neutral wire (N)
2 - Phase wire (up)
3 - Phase wire (down)
PE - Ground wire
Blue Black Brown Yellow-green
Содержание Cetta 35
Страница 1: ...Technical manual INTERIOR BLINDS EN...
Страница 26: ...26 The Blind is installed according to norm EN 13120 about security elements Isolite Plus Assembly...
Страница 30: ...30 Neoisolite Assembly The Blind is installed according to norm EN 13120 about security elements...
Страница 32: ...32 System 25 Control rotary button handle cord wand in between glass panels chain large...
Страница 52: ...52 Isotra System 25 Large Assembly The Blind is installed according to norm EN 13120 about security elements...
Страница 56: ...56 The Blind is installed according to norm EN 13120 about security elements Isotra Energy Assembly...
Страница 83: ...83 INTERIOR BLINDS 83 Connected Blind Measuring...
Страница 85: ...85 INTERIOR BLINDS 85 6 7 8 9 10 11...
Страница 86: ...86 86 12 13 14 15 16 17...
Страница 88: ...88 88 Notes...
Страница 97: ...97 INTERIOR BLINDS...
Страница 98: ...98 Notes...
Страница 99: ...99 INTERIOR BLINDS Notes...