User Manual
48
4.2 Ventilation
It is extremely important for the compressor/condensing unit located behind the
refrigerator to be well ventilated so that the fresh air can enter at the bottom and
pass behind the refrigerator, with the hot air being allowed to escape from the top
or sides (Fig. 1). The illustrations (Fig. 2-3) show an example of how the refrigerator
housing should be set.
4.3 Door Panelling
Cruise Classic refrigerators are supplied as standard with gray door panels. Optional
panels are available in other colours and finishes.
Cruise Elegance refrigerators are supplied with silver aluminium door panels.
Optional panels are available in other colours and finishes.
Inox models come equipped with a stainless steel door without replaceable door
panels.
A replacement door panel can be installed over top of the standard gray panel on
Cruise Classic models. To do so, remove the lower plastic gasket, pulling it downward,
and then remove the door handle equipped with three screws (Fig. 10).
To change door panelling on Cruise Elegance models, delicately remove the 4 lateral
panel locking strips, remove the small handle frame and then it will be possible to
remove the panel. Insert the new panel and delicately reinstall the lateral strips and
the handle frame (Fig. 9).
This procedure is illustrated on our “Indel Webasto Marine”
channel.
4.4 Door Reversibility
The opening direction of Isotherm Cruise (not including CR200) & Cruise Elegance
refrigerator doors can be reversed to meet installation requirements.
To reverse the opening direction of the door in Cruise Classic and Inox models,
remove the screws securing the top (no top is present on Inox models) and the
fastening pins, remove the door, reverse the fastening hinges as illustrated (Fig.7)
and re-insert the door and re-tighten all parts. To reverse the opening direction of
the door in Cruise Elegance models, remove the screws securing the top and the
fastening pins, remove the door, reverse the fastening hinges as illustrated (Fig. 8)
and re-insert the door and re-tighten all parts.
Содержание CR 130
Страница 2: ......
Страница 3: ...3 Isotherm Cruise Serie Fig 1 Fig 2...
Страница 4: ...4 Isotherm Cruise Serie Fig 3 Fig 4...
Страница 5: ...5 Isotherm Cruise Serie Fig 5 Fig 6...
Страница 6: ...6 Isotherm Cruise Serie Fig 7 Fig 8...
Страница 7: ...7 Isotherm Cruise Serie Fig 9 Fig 10...
Страница 8: ...8 Isotherm Cruise Serie Fig 11 Fig 12...
Страница 218: ...218 1...
Страница 219: ...219 INDEL Webasto Marine S r l 1 2 2002 96 RAEE...
Страница 220: ...220 R134a R134a R134a 1 3 Indel Webasto Marine S r l...
Страница 221: ...221...
Страница 222: ...222 115 230 8...
Страница 223: ...223 2 SN 10 C 32 C N 16 C 32 C ST 16 C 38 C T 16 C 43 C 2 1 5 6 C...
Страница 224: ...224 2 2 6 Indel Webasto Marine S r l 30...
Страница 225: ...225 2 3 3 4 0 3 Isotherm Cruise Cruise Elegance 0 C...
Страница 226: ...226 Classic Classic 5 Elegance Elegance TO VENT 6 3 1 12 9 6 10 4 10 9 11 7 24 21 3 22 8 22 7 24 2...
Страница 227: ...227 4 Indel Webasto Marine S r l...
Страница 228: ...228 EN 603 335 1 5 Heavy Current Regulations 115 230...
Страница 229: ...229 4 1 Isotherm 30 CR42 1 5 Elegance Easy Fix 12 Easy Fix Cruise Elegance 10 11 2 EN 60335 2 24...
Страница 232: ...232 4 6 2 AWG 12 24 2 5 13 2 5 8 5 16 4 11 4 13 8 26 6 9 6 19 12 39 10 7 10 33 20 66 4 7 4 Indel Webasto Marine Srl...
Страница 235: ...235 6 T C R134a...
Страница 236: ...236 4 4 C P C T...
Страница 237: ...237 Indel Webasto Marine Isotherm...
Страница 238: ...238 7 6 5 4 1 850 3 5 2 1A 1...
Страница 241: ...241 9 Indel Webasto Marine 1999 44 Isotherm 2 IWM b S N...
Страница 243: ...243 Isotherm Cruise Standar Cruise DC 12 24 Volt...
Страница 244: ...244 Isotherm Cruise Standar Cruise AC DC 12 24 Volt 115 230 Volt...
Страница 245: ...245 Isotherm Cruise Cruise CR130 DRINK DC 12 24 Volt...
Страница 246: ...246 Isotherm Cruise Cruise CR130 DRINK AC DC 12 24 Volt 115 230 Volt...
Страница 247: ......