background image

 

11 

 

Reserve polarity protection 

Present 

Overload current protection 

Present 

Power Supply 

PW1 and PW2 for Redundant Dual DC46~57V   

PW3 for Power DIN to connect external power adapter DC 

46-57V 

For Switch only --- Power input range DC 12-56VDC 

For POE --- Power input range 46-57VDC 

Power Consumption 

5.76W@48 VDC full load, Without POE 

Alarm Relay Contact 

Relay outputs with current carrying capacity of 1 A 

@24VDC, for PW1 and PW2 

Relay in open circuit mode when 2 powers are connected. 

In short circuit mode when only one power supply is 

connected 

POE power 

Input Voltage 48VDC-56VDC. 

POE power per port 30watts. Maximum 36Watts with 

56VDC input. 

Maximum total power 200Watts with 56VDC input 

Removable Terminal Block 

Provide 2 Redundant powers , Alarm relay contact ,6 Pin 

for PW1 and PW2 ( PW3 is an independent Power din 

connection for external power adapter) 

Wire range: 0.34mm^2 to 2.5mm^2 

Solid wire (AWG):12-24/14-22 

Stranded wire(AWG): 12-24/14-22 

Torque:5lb-In/0.5Nm/0.56Nm 

Wire Strip length: 7-8mm 

Operating Temperature 

-40

~75

  fully tested.   

Operating Humidity 

5% to 95% (Non-condensing) 

Storage Temperature 

-40

~85

 

MTBF (mean time between failure) 

490,304 hrs ( MIL-HDBK-217F) at 25°C 

Housing   

Rugged Metal ,IP30 Protection 

Case Dimension (L x W x D) 

142mmx47.3mmx135.3mm (LxWxD) 

Installation mounting   

DIN Rail mounting and Wall Mounting   

 

 

 

 

Содержание IS-DH310P-2F-8

Страница 1: ...be required to correct the interference at the own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful...

Страница 2: ...2 Copyright 2016 PRIMMCON Industries Inc All Rights Reserved...

Страница 3: ...per POE port also generate up to 200 watts power to PD devices The uplink 2 SFP port can extend to a wilder area connection With its multi purpose design that can also be used for Din Rail or wall mou...

Страница 4: ...4...

Страница 5: ...5 Housing Dimension IS DH310P 8 mm...

Страница 6: ...ion properly and may damage it To make power connection This unit can receive 3 power inputs PW1 PW2 and PW3 Follow the printed polarity for V1 V1 V2 V2 and ground Connect positive wire to V connect n...

Страница 7: ...al block to its place For PW3 connection Use an external industrial graded power adapter to make proper connection Follow the priority sign V V WARNING Always ground the power source to remain a clean...

Страница 8: ...FP fiber is not detected Flashing port 9 SFP fiber is active Port 2 Green ON port 10 SFP fiber is detected OFF port 10 SFP fiber is not detected Flashing port 10 SFP fiber is active P1 Green ON when V...

Страница 9: ...nected P2 Green ON when V2 V2 is connected P3 Amber ON when V3 V3 is connected ALM Amber ON PW1 or PW2 is connected OFF PW1 PW2 are connected Port 3 to 10 LNK Green ON TX link is detected OFF TX port...

Страница 10: ...otiation 8 10 100M POE 802 3at af PSE port 2 x 1000M SFP IS DH310P 2F 8 2xRJ 45 10 100 1000BaseT X auto negotiation IS DH310P 8 Auto MDI MDI X function Full Half duplex Network Cable UTP STP Cat 5e or...

Страница 11: ...Voltage 48VDC 56VDC POE power per port 30watts Maximum 36Watts with 56VDC input Maximum total power 200Watts with 56VDC input Removable Terminal Block Provide 2 Redundant powers Alarm relay contact 6...

Страница 12: ...55011 Industrial Scientific and Medical ISM equipment Safety IEC EN60950 1 EMC EMS CE FCC VCCI EMI FCC Part 15 Subpart B Class A CE EN 55022 Class A EN 50155 EN 60068 2 6 Vibration EN 50155 EN 60068 2...

Отзывы: