3
Power connection
The provided 4 pin terminal block can be connected with 48VDC to 56VDC power source. Always Make
sure your input voltage is within this supported voltage range.
To make power connection – Follow the printed polarity for V+, V-, Ground. Connect positive wire to V+ ,
connect negative wire to V-, also connect neutral wire to ground. This unit can be connected to two power
input.
+V1- is for power input one connection,
+V2-(SW) is for power input two connection.
Din Rail Bracket x 1
Wall mount bracket x 2
4 pin Terminal Block x1
Installation package
This unit can be installed by din-rail mounted or wall-mounted. Din-rail brackets and wall-mounted bracket
are included.
Connecting procedure
STEP 1 –
Take out 4 pin terminal block located in the included mounting kit package.
STEP 2 –
Connect power wire to +V1- or CV2- (SW) as shown above
STEP 3 –
Plug into terminal block socket shown above. Polarity needs to match the V+ and V-
WARNING -- Always SHUTS OFF power source to connect power wire.
WARNING – any exceeded input voltage will not make this unit function and may damage this unit.
(SW)
+ V1 - + V2 -
Содержание IS-DG102P-1