Power connection
This unit provides 3 pin terminal block. And it can be operated using either VAC or VDC power
source. The VDC power range is from 12VDC to 60VDC, and the VAC power range is from 18VAC
to 36VAC. Always Make sure your input voltage is within this supported voltage
range.
WARNING – any exceeded input voltage will not make this unit function and
may damage this unit.
To make power connection – Follow the printed polarity for V+, V-, Ground. Connect positive wire
to V+ , connect negative wire to V-, also connect neutral wire to ground.
Connecting procedure
STEP 1 –
Pull out 3 pin terminal block.
STEP 2 –
connect wire to V+, V-, and Ground
STEP 3 –
Connect SFP fiber connector or SC fiber wire to fiber port.
STEP 4 – plug back 3 pin terminal block to its place.
WARNING -- Always pull out terminal block to connect power wire. DONOT force SFP fiber into
Din Rail Bracket x 1
Wall mount bracket x 2
3 pin Terminal Block x1
Installation package
This unit can be installed by din-rail mounted or wall-mounted. Din-rail brackets and wall-
mounted bracket are included.