    1.   Safety   Instructions       

   

 

   

WARNING

   

Please   keep   this   User   Guide   for   future   consultation.   If   you   sell   the   unit   to   another   user,   be   sure   
that   they   also   receive   this   instruction   manual.   

Ÿ

 

Unpack   and   check   carefully   there   is   no   transportation   damage   before   using   the   unit.   

Ÿ

 

Before    operating,    ensure    that    the    voltage    and    frequency    of    power    supply    match    the    power   

requirements   of   the   unit.       

Ÿ

 

It’s   important   to   ground   the   yellow/green   conductor   to   earth   in   order   to   avoid   electric   shock.   

Ÿ

 

The   unit   is   for   indoor   use   only.   Use   only   in   a   dry   location.   

Ÿ

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   least   50cm   from   adjacent   

surfaces.   Be   sure   that   no   ventilation   slots   are   blocked.       

Ÿ

 

Disconnect   main   power   before   replacement   or   servicing.       

Ÿ

 

Make   sure   there   are   no   flammable   materials   close   to   the   unit   while   operating   as   they   may   be   a   

fire   hazard.       

Ÿ

 

Use   safety   cables   when   installing   this   unit.   DO   NOT   handle   the   unit   with   its   head   only,   always   

carry   by   its   base.           

Ÿ

 

Maximum   ambient   temperature   is   Ta:   40   degrees   C.   DO   NOT   operate   it   where   the   temperature   

is   higher   than   this.   

Ÿ

 

Turn   off   the   power   and   allow   about   15   minutes   for   the   unit   to   cool   down   before   replacing   or   

servicing.   

Ÿ

 

In   the   event   of   a   serious   operating   problem,   stop   using   the   unit   immediately.   Never   try   to   repair   

the   unit   by   yourself.   Repairs   carried   out   by   unskilled   people   can   lead   to   damage   or   malfunction.   

Please    contact    the    nearest    authorized    technical    assistance    center.    Always    use    the    same    type   

spare   parts.   

Ÿ

 

DO   NOT   touch   any   power   cables   during   operation   as   high   voltage   may   cause   electric   shock.   

Please   read   the   instructions   carefully   as   they   include   important   

information   about   installation,   usage   and   maintenance.   

Содержание iMove 150

Страница 1: ...Order Code ISIM29 User Manual Please read the instructions carefully before use...

Страница 2: ...verview 4 3 2 Gobo Wheel 6 3 3 Main Functions 6 3 4 Home Position Adjustment 12 4 How to Control the Unit 13 4 1 Master Slave Built In Preprogrammed Function 13 4 2 CA 8 Easy Controller 14 4 3 DMX Con...

Страница 3: ...Make sure there are no flammable materials close to the unit while operating as they may be a fire hazard Use safety cables when installing this unit DO NOT handle the unit with its head only always...

Страница 4: ...cable that can hold 12 times of the weight of the fixture when installing The equipment must be installed by professionals It must be installed in a place where is out of the reach of people and no on...

Страница 5: ...1 LED DMX On DMX input present MASTER On Master Mode SLAVE On Slave Mode SOUND Flashing Sound activation 2 Button MENU To select the programming functions DOWN To go backward in the selected function...

Страница 6: ...DMX OUT DMX 512 link use a 3 pin DMX cable to link the next unit and the output DMX signal 5 Only For Remote Control Connects to optional CA 8 controller to control the unit in Stand by Function and S...

Страница 7: ...d the display will blink Use the DOWN UP buttons to change the mode Once the required mode has been selected press the ENTER button to setup To go back to the functions without any changes press the M...

Страница 8: ...XTURE HOURS MENU SOFTWARE VERSION LED DISPLAY OFF LED DISPLAY ON DISPLAY INVERSION NORMAL SLAVE MODE BLACKOUT MODE SOUND MODE TEST SOUND SENSE RESET NORMAL PAN INVERSION NORMAL TILT INVERSION TEMPERAT...

Страница 9: ...n Press and hold the MENU button for about one second or wait for one minute to exit the menu mode SHOW MODE To select press the ENTER button to show the SHOW MODE on the display Use the DOWN UP butto...

Страница 10: ...U button again Press and hold the MENU button for about one second or wait for 7 seconds to exit the menu mode SOUND MODE To select press the ENTER button to show the SOUND MODE on the display Use the...

Страница 11: ...nu mode Display normal mode for floor standing fixture Display inversion mode for ceiling or truss mounting LED DISPLAY To select press the ENTER button to show the LED DISPLAY on the display Use the...

Страница 12: ...u mode TEMPERATURE To select press the ENTER button to show the TEMPERATURE on the display To go back to the functions without any changes press the MENU button again Press and hold the MENU button fo...

Страница 13: ...alue from 127 to 127 press the ENTER button to store Press the MENU button to exit Tilt home position adjustment To select press the ENTER button to show the TILT OFFSET on the display Use the DOWN an...

Страница 14: ...some noises for about 20 seconds After that the unit will be ready to receive a DMX signal or run the built in programs 4 1 Master Slave Built In Pre programmed Function By linking the units in maste...

Страница 15: ...Strobe 2 Async strobe 3 Sound Strobe Show 1 4 1 Press to select colour 2 Hold to select gobo Mode Sound LED OFF Show LED Slow Blinking LED ON 4 3 DMX Controller If you are using a universal DMX contro...

Страница 16: ...5 Open 016 131 Strobe Slow to Fast 132 139 Open 140 181 Slow Open Fast Close 182 189 Open 190 231 Fast Open Slow Close 232 239 Open 240 247 Random Strobe 248 255 Open 4 COLOUR 000 007 white 008 014 Co...

Страница 17: ...shaking 111 119 Gobo5 shaking 120 127 Gobo6 shaking 128 189 Clockwise Gobo Scroll Fast to Slow 190 193 Stop 194 255 Counter Clockwise Gobo Scroll Slow to Fast 6 GOBO ROTATION 000 009 Stop 010 119 Cloc...

Страница 18: ...139 Open 140 181 Slow Open Fast Close 182 189 Open 190 231 Fast Open Slow Close 232 239 Open 240 247 Random Strobe 248 255 Open 6 COLOUR 000 007 white 008 014 Colour1 015 021 Colour2 022 028 Colour3 0...

Страница 19: ...e Gobo Scroll Fast to Slow 190 193 Stop 194 255 Counter Clockwise Gobo Scroll Slow to Fast 8 GOBO ROTATION 000 009 Stop 010 119 Clockwise Rotation fast to slow 120 134 Stop 135 245 Clockwise Rotation...

Страница 20: ...3 Connect the units together in a daisy chain by using a DMX cable from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable The DMX output and input c...

Страница 21: ...D is on and no response to the controller check the address settings and DMX polarity 3 Try another DMX controller C Some fixtures don t respond to the CA 8 Easy controller 1 You may have a break in t...

Страница 22: ...ends on the environment in which the fixture operates moist smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture Clean with a soft cloth using normal glass cle...

Страница 23: ...h the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598...

Страница 24: ...23 Innovation Quality Performance...

Отзывы: