background image

3

98-05267-EN R3

IC18 Sprayer/NH3 OEM options

Sensor Presence

Figure 1-4: Sensor Presence - Sprayer Mode

 

Figure 1-5: Sensor Presence - NH3 Mode

Figure 1-6: Implement Parameters - Sprayer Mode

Figure 1-7: Implement Parameters - NH3 Mode

Sensor Presence establishes sensors for Flow, Liquid Pressure, Fill Flow and the 

Tank.  If the fitted sensors are not registered here, the sensor options will not be 

available in the calibration menus.  

Flow Sensor

Flow Sensor sets the associated sensor availability to yes or no.

• 

To set the Flow Sensor, select an option from the drop down menu or use the 

UP/DOWN ARROWS to highlight the option.

Liquid Pressure Sensor

Liquid Pressure Sensor sets the associated sensor availability to yes or no.

• 

To set the Liquid Pressure Sensor, select an option from the drop down menu 

or use the UP/DOWN ARROWS to highlight the option.

Fill Flow Sensor (Sprayer Mode)

Fill Flow Sensor sets the associated sensor availability to yes or no. Available only 

in Sprayer Mode.

• 

To set the Fill Flow Sensor, select an option from the drop down menu or use 

the UP/DOWN ARROWS to highlight the option.

Tank Sensor (Sprayer Mode)

Tank Sensor sets the associated sensor availability to yes or no. Available only in 

Sprayer Mode.

• 

To set the Tank Sensor, select an option from the drop down menu or use the 

UP/DOWN ARROWS to highlight the option.

Implement Parameters

Implement Parameters establishes the Sprayer Mode, Number of Sections and if 

there is tank Circulation.

Sprayer Mode

Sprayer Mode sets the implement parameter to either Crop Sprayer, Turf or NH3.

• 

To set the Sprayer Mode, select an option from the drop down menu or use 

the UP/DOWN ARROWS to highlight the option.

NOTE:  When sprayer mode is changed, power must be cycled before all settings 

will be displayed correctly.

Number of Sections

Number of Sections establishes how many sections are on the boom.
NOTE:  The number established here affects options under Main -> Implement 

Parameters -> Section Width -> Boom Section Width and on the 

Operations Screen.

• 

To set the Number of Sections, use the number pad or slide bar.

Circulation (Sprayer Mode)

Circulation sets if there is No, Semi or Full tank circulation. Available only in 

Sprayer Mode.

• 

To set the Circulation, select an option from the drop down menu or use the 

UP/DOWN ARROWS to highlight the option.

NOTE:  For this option to appear, Sprayer Mode must be set to Crop Sprayer.

Содержание TeeJet IC18

Страница 1: ...IC18 SPRAYER NH3 JOB COMPUTER O E M M E N U S E T U P Software version 1 09 ...

Страница 2: ...ffset Sprayer Mode 4 Regulation Details 5 Minimum Regulation Pressure 5 Maximum Regulation Pressure 5 Regulation Valve Time 5 Minimum Regulation Voltage 5 Regulation Dead Band 5 Regulation Backlash 5 Anticipation Factor 5 Default Valve Position 5 Regulation Valve Capacity 5 Regulation Start Delay 6 Minimum Speed 6 Manual Regulation Speed 6 Restrictor Plate Flow Sprayer Mode 6 Clear Total Counters ...

Страница 3: ...ay might vary from the one displayed in this User Manual depending on the universal terminal being used Figure 1 1 Soft Keys Home Key Back One Screen Up One Selection Down One Selection Forward One Screen MAIN SETUP MODE MENU STRUCTURE Counters Job Parameters Machine User Interface Communication Help Filling Operation Implement parameters Calibrations Alarm configurations OEM Sensor presence Imple...

Страница 4: ...sor presence used to establish sensors for Flow Liquid Pressure Fill Flow and the Tank Implement parameters used to establish the Sprayer Mode Number of Sections and Circulation Valve setup used to establish the Regulation Valve Type Section Valve Behavior and Section Valve Type Tank setup used to establish maximum and minimum tank content Auto Filling mode and Auto Filling Offset value Regulation...

Страница 5: ...ht the option Tank Sensor Sprayer Mode Tank Sensor sets the associated sensor availability to yes or no Available only in Sprayer Mode To set the Tank Sensor select an option from the drop down menu or use the UP DOWN ARROWS to highlight the option Implement Parameters Implement Parameters establishes the Sprayer Mode Number of Sections and if there is tank Circulation Sprayer Mode Sprayer Mode se...

Страница 6: ...f Mode To set the Section Valve Type select an option from the drop down menu or use the UP DOWN ARROWS to highlight the option Tank Setup Tank Setup establishes maximum and minimum tank content Auto Filling mode and Auto Filling Offset value Maximum Content Maximum Content establishes the maximum tank volume To set the Maximum Content use the number pad or slide bar Minimum Content Minimum Conten...

Страница 7: ... rate the lower the voltage sent to the valve is The minimum voltage must therefore be found when the valve is under pressure as this affects the force required to move the valve To set the Minimum Regulation Voltage use the number pad or slide bar Regulation Dead Band Regulation Dead Band establishes an acceptable regulation dead band in percent Regulation will stop when the difference between th...

Страница 8: ...ulation Speed use the number pad or slide bar Restrictor Plate Flow Sprayer Mode Restrictor Plate Flow establishes the capacity of the restrictor plate in volume per minute and is to be used when working with return flow circulation Available only in Sprayer Mode To set the Restrictor Plate Flow use the number pad or slide bar Clear Total Counters Figure 1 13 Clear Total Counters Sprayer Mode Figu...

Страница 9: ... will vary depending on the parameters set by the user and the OEM Figure 1 16 Operation Mode Screen Overview Pressure Range Target Rate Percentage Increase Decrease Target Rate Indicator Current Pressure Rate Section and Icon Descriptions Section or Icon Description Application Rate Displays the actual application rate per hectare acre NOTE When the Master is On the actual application rate per he...

Страница 10: ... the Target Rate press the BOOST STEP INCREASE DECREASE KEYS Target Rate Preset Application Rates define up to five 5 target rates of product being applied per hectare acre These settings will set the same for all active trips Target rates set to 0 0 will not be included in the toggle preset target rate options on the Operation Screen or Home Screen If a switchbox is being used to control the boom...

Страница 11: ...TION OF LIABILITY TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED NO COPYRIGHT LIABILITY OR PATENT IS ASSUMED IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS LOSS OF PROFIT LOSS OF USE OR DATA INTERRUPTION OF BUSINESS OR FOR INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND EVEN IF TEEJET TECHNOLOGIES...

Страница 12: ...IC18 SPRAYER NH3 JOB COMPUTER O E M M E N U S E T U P www teejet com 98 05267 EN A4 R3 English TeeJet Technologies 2016 SOFTWARE VERSION 1 09 ...

Отзывы: