Iso ISOJET Cleaner 5 Скачать руководство пользователя страница 4

DEUTSCH

FRANÇAIS

ENGLISH

Important Notice regarding Product Liability

According to the since 01.01.1990 valid EU-Guidelines, the manufacturer is only then liable for
the product when all parts of the device originate from the manufacturer and the device was
correctly assembled and operated.
With the use of foreign accessories or parts, the liability and guarantee of the manufacturer
either falls away entirely or partly.
By using the Carbon Cleaner 5 accessories and parts, you have the guarantee that all the safety
requirements are adhered to and you also profit from the continual product development.

Safety Guidelines and Requirements

The Cleaner can only then be operated risk-free when all the safety guidelines are read and
adhered to in its entirety.
1.  The use of the Cleaner is only permissible in the commercial and industrial area.
2.  Keep the workplace tidy. Untidy workplaces favours the possibility of an accident.
3.  Protect your eyes with safety goggles or a face shield.
4.  To protect your hands from allergies (e.g. Nickel), use Latex, Vinyl gloves or similar.
5.  Ensure that there is sufficient air flow. Use an extraction system if possible.
6.  Take  your  environment  into  consideration.  Ensure  good  lighting.  Do  not  use  the  cleaner  near 

flammable substances or where a spark can ensure.

7.  Keep away from children. The chemicals contain partly poisonous substances.
8.  The person operating the devise must be at least 18 years old. Trainees must be at least 16 years 

old und be under supervision.

9.  Electromagnetic fields can interfere with pacemakers. Persons using such, are prohibited from 

using the Cleaner.

10. Do not overwork the Cleaner. Do not cause any shorts. You operate much better and safer within 

the given performance parameters.

11. Use the correct tools. Use the attachments purposefully (carbon brushes / electrodes).
12. Wear suitable clothing. The chemicals can cause colouration on your clothes.
13. Use the cable and pipes for its intended use. Do not carry the Cleaner by the cable. Check the 

cable and pipes regularly for any damages and replace them timeously.

14. Secure the work piece. Use holding devices to secure the work pieces as this is safer than holding 

it with your hand.

15. Keep a normal body position and do not overstretch yourself.
16. Keep your balance at all times.
17. Take special care of your Cleaner. 
18. Keep the device clean. Wash it with soap water or Carbon Cleaner 5 N.
19. Unplug the device from the mains when not using it.
20.  Avoid the unintentional use of the device. 
21. Make sure that the device is not in contact with tools, materials, tables etc. and starts working on 

its own.

Содержание ISOJET Cleaner 5

Страница 1: ...UTSCH FRANÇAIS ENGLISH Aktion Aktion Print AD 17 04 Print AD 17 04 Welding with you Operating Instructions to ISOJET Carbon Cleaner 5 Operating Instructions to ISOJET Carbon Cleaner 5 Red 110 V Blue 230 V ...

Страница 2: ... unauthorized by ISO ELEKTRODENFABRIK AG shall immediately invalidate this statement Eingriffe und Änderungen ohne die Genehmigung von ISO ELEKTRODENFABRIK AG machen die vorliegende Erklärung ungültig Toute opération ou modifi cation non autorisées par ISO ELEKTRODENFABRIK AG feront déchoir la validité de cette déclaration Cualquier intervención o modifi cación no autorizadas por ISO ELEKTRODENFAB...

Страница 3: ...dling The Set Up times are minimal Plug in and work a few changes of handles and you are able to clean on flat surfaces in the corner welds and in difficult to reach corners just as easy thanks to the Carbon Technology Once you have completed the job the cleaner is dismantled just as fast as it was assembled The extremely durable robust Stainless Steel construction was designed for tough workshop ...

Страница 4: ...good lighting Do not use the cleaner near flammable substances or where a spark can ensure 7 Keep away from children The chemicals contain partly poisonous substances 8 The person operating the devise must be at least 18 years old Trainees must be at least 16 years old und be under supervision 9 Electromagnetic fields can interfere with pacemakers Persons using such are prohibited from using the C...

Страница 5: ...rom the bubble pack The rest of the replacement brushes and refill container ISO JET ISOL C can be stored in its original packaging for later as these are usually only required later Unwind the cable from the drum and connect the device according to the drawing Should the work piece not allow a direct attachment of the earth clamp you can still get a connection using a clamp or locking pliers etc ...

Страница 6: ... the plug Diagram Work Piece Connection Carbon brush assembly to the applicator handle You received 5 carbon brushes in the standard set These almost cover every possible area of application and can be used for fl at welds corner welds as well as diffi cult to reach corners Attention 1 Do not tilt when screwing on 2 The thread should turn smoothly 3 Occasionally check for oxidation and clean if ne...

Страница 7: ...h came with the devise This special container with its wide opening is optimal for safe use It also can be closed tightly after use Please note During use the electrolyte becomes increasingly black This discolouration is quite normal and generally does not infl uence the cleaning process When the container is empty dry it with absorbent paper and refi ll with new electrolytic substance from the re...

Страница 8: ... the brush to wear faster Be aware that the current is doing the work Avoid scrubbing the brushing unit on the work piece Correct Incorrect Using this method the result is not always visible immediately Tipp By wiping with a moist cloth the result is quickly seen and removes excess electrolyte solution Attention Tighten only gently by hand Should the brush not have been in use for some time screw ...

Страница 9: ...ger conductive These have to be removed mechanically Take note of any excess running electrolytic solution It can cause ugly runs Excess electrolytic solution can be removed from the work piece using the cloth and some water Because of the oxide residue the weld is generally always cleaned with water In special applications Carbon Cleaner 5 N using the pump spray can we used This product neutralis...

Страница 10: ...onnect to the power source Check the clamp connection Clean the clamps Is applicator properly attached Dip the brush into electrolyte Allow the power source to cool off Problem Cause Solution Wave effect Too little brush movement Move the brush more Poor cleaning Brush is worn Contact error brush Contact error unit Diluted electrolytes Welds are nearly burnt Replace the brush Clean the thread Chec...

Страница 11: ...EU Schuko PU 1 pc Consumables K7000010 Carbon brushes PU 5 pcs K7000011 ISOL C 250 ml PU 1 pc K7000012 ISOL C 1000 ml PU 1 pc 5575000 Carbon Cleaner 5 Spray 250 ml PU 1 pc renalp ISOJET MCT 201 400 g PU 1 pc renalpg ISOJET MCT 201 1000g PU 1 pc 007hs ISOJET ISO MAGIC 750 ml PU 1 pc 00744lt ISOJET ISO MAGIC 5000 ml PU 1 pc corylS ISOJET MCT 800 Spray 400 ml PU 1 pc corsyl ISOJET MCT 800 Fluid 1000 ...

Страница 12: ...DEUTSCH FRANÇAIS ENGLISH Spare Part 1 Handle 6 Rear cover 2 Cover 7 Trafo 3 Mains cable 8 Front cover 4 Straight clamp round cable 9 Green Led 5 Bipolar switch 10 Dinse ...

Страница 13: ...DEUTSCH FRANÇAIS ENGLISH ...

Страница 14: ...cifications ISOJET Cleaner 5 Cleaner 5 230 V Cleaner 5 110 V CE EN 61588 1 2006 42 61588 1 2006 42 Main voltage 230V 50 60 Hz 110V 50 60 Hz Fuse 1Ph 10A 1Ph 10A Insulation classifi cation IP 23S Duty cycle AC 25A 100 ED OCV 12V Betriebsanleitung TZ GF EN ...

Отзывы: