8
3.3.2 A.c. voltage (Va.c.)
Range
Resolution
Accuracy
Over Voltage
protection
600Vd.c. or
600V rms
4V
1µV
±
(1% + 5D)
50 to 60Hz
±
(1.5% + 5D)
50 to 60Hz
40V
10µV
400V
100mV
600V
1V
Input impedance:
10M
Ω
in parallel with less than 100pF.
A.c. voltage conversion:
Mean measured - r.m.s. value displayed.
3.3.3 D.c. current (Ad.c.)
Range
Resolution
Accuracy
Voltage drop
4mA
1µA
±
(0.8% + 2D)
40mA
10µA
400mA
0.1mA
10A
10mA
±
(1.5% + 4D)
1V (max.)
800mV (max.)
Содержание IDM101
Страница 1: ...Instruction Manual IDM101 Digital Multimeter EN FR IT DE JP...
Страница 2: ...1 ISO TECH IDM101 Digital Multimeter INSTRUCTION MANUAL...
Страница 3: ...2...
Страница 15: ...14 Figure 1 1 7 8 9 10 14 13 12 11 2 3 4 5 6...
Страница 20: ...19 Fig 2 Changing batteries Bottom half of case Top half of case 1 5V battery Battery holder...
Страница 22: ...21 Fig 3 Changing fuses Top half of case Bottom half of case 10A 415V fuse 1A 415V fuse Fuse holder...