17
5.5 Continuity testing with the internal sounder
1. Plug the black lead into the "COM" input terminal and the red lead into the "V
Ω
<
" input terminal.
2. Turn the function switch to "
Ω
” and use the function button to set to continuity testing ("
" will appear on the display).
3. Apply the probes to the circuit to be tested. The internal sounder will operate if the resistance is less than about 40
Ω
.
5.6 Diode testing
1. Turn the function switch to "
" and use the function button to select diode testing ("
").
2. Plug the black lead into the "COM" input terminal and the red lead into the "V -
Ω
-
" input terminal. (Note: The red lead is
positive.)
3. Apply the probes to the diode to be tested. With a non-faulty silicon diode, the voltage shown in the forward direction will
be between 0.500 and 0.900V. With a faulty diode, "000" (short-circuit) or a reading of approx. 3.2V (open circuit) will
be shown.
4. When tested in the opposite direction (blocking direction), a reading of approx. 3.2V will appear for a non-faulty diode and
"000" (short circuit) or a different reading of less than 3.2V for a faulty one.
5.7 Measuring capacitance
1. Plug the black lead into the "COM" input terminal and the red lead into the "V -
Ω
-
" input terminal.
2. Turn the function switch to "
" and use the function button to select capacitance measurement (
).
3. When measuring the capacitance of polarised capacitors be sure to apply the probes with the correct polarity.
4. Apply the probes to the capacitor whose capacitance you wish to measure.
Important :
1. The capacitor must be fully discharged before any measurements are made.
2. To obtain a more accurate measurement you are advised to use the relative mode (press REL button) to
correct for any stray capacitances.
Содержание IDM101
Страница 1: ...Instruction Manual IDM101 Digital Multimeter EN FR IT DE JP...
Страница 2: ...1 ISO TECH IDM101 Digital Multimeter INSTRUCTION MANUAL...
Страница 3: ...2...
Страница 15: ...14 Figure 1 1 7 8 9 10 14 13 12 11 2 3 4 5 6...
Страница 20: ...19 Fig 2 Changing batteries Bottom half of case Top half of case 1 5V battery Battery holder...
Страница 22: ...21 Fig 3 Changing fuses Top half of case Bottom half of case 10A 415V fuse 1A 415V fuse Fuse holder...