background image

o

 MAX: The clamp-multimeter stores the 

    maximum and minimum values. The  
    maximum value is displayed. 

p

 MIN: The clamp-multimeter stores the  

    maximum and minimum value. The  
    minimum value is displayed. 

q

 MAX MIN (flashing) :  

    The clamp-multimeter stores the  
    maximum and minimum values.  
    The present value is displayed. 

n

 Normal: Press and hold the MIN MAX  

    button to return to normal operation.

 

Min / Max Hold

 

Battery Replacement

 

 

Warning :

 

Disconnect the clamp-

multimeter from all power sources and 
remove it from around a conductor before 
removing the battery compartment cover. 

Replace battery:  

Replace the battery when the low battery 
symbol  “

” appears on the display.

 

Содержание ICM 136R

Страница 1: ...Instruction Manual ICM 136R Electrical Clamp Multimeter EN FR IT DE ES ...

Страница 2: ...ion provided by it may be impaired Use extreme caution and wear Personal Protective Equipment when taking measurements where Hazardous Live parts could be Accessible Use caution when measuring or working near voltages above 30 V ac rms or 60 V dc These voltages may cause a shock Do not allow fingers to protrude beyond the Tactile Barrier when fitting or removing the instrument from around a Hazard...

Страница 3: ...cal danger and risk of electrical injury such as from inadvertent short circuits Where the assessments show that the risk is significant then the use of fused test leads constructed in accordance with HSE guidance note GS38 Electrical Test Equipment for use by Electricians should be used Maintenance Do not attempt to repair the clamp multimeter It contains no user serviceable parts Contact RS Comp...

Страница 4: ...4 On Off Auto Power Off Auto Power Off disable Press any button except the Hold button or rotate the rotary switch to reset the Auto Power Off function and turn the clamp multimeter on 30min AC V DC V ...

Страница 5: ...5 Resistance Continuity ...

Страница 6: ...6 ACA DCA 590A I I I I OK OK OK I I 0 CAT Ⅲ 600V with respect to earth for the jaw Tactile Barrier for hand guard Do not hold the meter across the Tactile Barrier ACA 50Hz Hz ...

Страница 7: ...ress the ZERO button first time The LCD is displaying the relative value p REL flashing Meter saved the offset value Present value is displaying n Normal Press and hold ZERO for 2 sec to return to normal operation and cancel the offset value Data Hold 0A 190A ...

Страница 8: ...p multimeter stores the maximum and minimum values The present value is displayed n Normal Press and hold the MIN MAX button to return to normal operation Min Max Hold Battery Replacement Warning Disconnect the clamp multimeter from all power sources and remove it from around a conductor before removing the battery compartment cover Replace battery Replace the battery when the low battery symbol a...

Страница 9: ...imeter stores the peak maximum and minimum values The peak minimum value is displayed q CAL Press and hold the PEAK button 3 sec to calibrate the clamp multimeter for accurate measurement n Normal Press and hold the PEAK button to return to normal operation Back Light The back light will automatically turn off after approximately 60 seconds ...

Страница 10: ... only Calibration One year calibration cycle Operating temperature 0 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage temperature 20 to 60 C 0 to 80 RH batteries not fitted Overvoltage category IEC 61010 1 600V CAT Ⅲ CAT Ⅲ equipment is designed to protect against the transients in the equipment in fixed installations such as distribution panels feeders and short branch circuits and lighting sy...

Страница 11: ... input Accuracies are given for sine wave at full scale and non sine wave below half scale For non sine wave add the following Crest Factor corrections For Crest Factor of 1 4 to 2 0 add 1 0 to accuracy For Crest Factor of 2 0 to 2 5 add 2 5 to accuracy For Crest Factor of 2 5 to 3 0 add 4 0 to accuracy CF 3 400A 400V 2 600A 600V 1 3 Electrical Specifications Accuracy is reading number of digits a...

Страница 12: ...y is same as AC Voltage Position Error 1 of reading Function Range Accuracy A 50 60Hz 0 60 0A 1 9 7 digits 60 1 400 0A 1 9 5 digits 1 400 600A A 61 400Hz 0 60 0A 400 600A 2 5 7 digits 2 5 5 digits 2 9 5 digits 60 0 400 0A 2 5 5 digits 1 DC Current Function Range Accuracy A 0 60 0A 1 5 10 digits 60 0 400 0A 1 9 5 digits 400 600A 1 9 10 digits Overload protection 600 Arms Position Error 1 of reading...

Страница 13: ...ed warranties of merchantability and fitness for a particular purpose are limited to the above The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expense or economic loss Some states or countries laws vary so the above limitations or exclusions may not apply to you ...

Страница 14: ...so Tech PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Canada 1701 Woodward Drive Ste 108 Ottawa Ontario K2C 0R4 Canada Japan West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan South America Av Pdte Eduardo Frei M 6001 71 Centro Empresas El Cortijo Conchali Santiago Chile ...

Отзывы: