Caution !!
Before starting each sanitation cycle, it is mandatory to ensure that there are
no people or other living beings within the environment to be treated as potentially harmful UVC
radiation is used.
The presence detection system is always active for safety reasons; this determines the block also outside the
sanitation cycles. It will therefore be necessary to press the reset command before starting.
The timer emits an intermittent sound of about 10 sec, at the end of the work session, only when the cycle
is carried out correctly for the entire set time.
TIME OF USE HUNTER
Referring to the declared irradiance for each of the lamps used in terms of UVC energy, 1.7 w / m² at a distance
of one meter.
In relation to and to the doses reported in official tables for the destruction of microorganisms, we can indicate
that, with the cycles shown below in the different configurations, 99% of bacteria are killed on the surfaces and
objects that are irradiated.
COMMANDS
For operation, the appliance is equipped with:
• Timer positioned in the upper part of the central column, for setting the time and starting the sanitation cycle
(detailed programming instructions are given in the paragraph relating to the timer)
• A reset button to the right of the timer to reactivate the system following the detection of movement in the
environment where it is positioned.
On the 4 sides of the base and on the top of the central column there are 5 IR presence detectors for interrupting
the sanitation cycle if someone is detected during the operation of the lamps.
From the locked condition, due to the intervention of the IR sensors, with the timer display off, it is possible to
reactivate the system by pressing the luminous reset button for a few seconds.
The start command of the sanitation cycle on the timer activates in a timer
that allows the operator to leave the room before the lamps are switched on.