The configuration of the UVC corner number and relative control console must be agreed upon when
ordering. The indications in this manual are only for descriptive purposes for the assembly and use of the
product.
CONNECTION TO THE ELECTRICITY NETWORK
as previously indicated, the UVC corner and control console components do not have electrical connections that connect them to each
other since the installation positions and therefore the cable lengths are unknown.
Any requests for customization with specific lengths must be indicated when ordering.
The UVC corner modules connect to the control console and to each other with the following types of electrical cables.
INPUT command console>
cable 3x1.5mm² Control console power supply on terminals n ° F - N and terminal board earthing
terminal F is equipped with a lock with a value of 3.15A
OUTPUT control console> INPUT I ° UVC corner
cable 3 x 0.75mm² ballast power supply 230Vac internal UVC lamp UVC corner
from terminal n ° 3 of the 230V phase console> to terminal n ° 1 C1F(connector 1)
from the console earth terminal> to terminal n ° 2 C1F (connector 1)
from terminal n ° 4 of the neutral 230V console> to terminal n ° 3 C1F (connector 1)
This connection is through in the case of sequential connections of several ceiling lights
4x 0.5mm² 12 Vdc line power IR sensor for presence detection
from terminal n° 5 positive 12Vdc
(
brown color
)
> to terminal n° 1 C2F (connector 2) (brown color)
from terminal n° 6 negative 12Vdc (black color) > to terminal n° 2 C2F (connector 2) (black color)
from terminal n° 7 NC contact line 12Vdc
(
gray color
)
> to terminal n° 3 C2F (connector 2) (yellow / green color
)
from terminal n° 8 NC contact line 12Vdc
(
yellow / green color
)
> to terminal n° 4 C2F (connector 2) (yellow / green color)
cavo 4x 0.5mm² IR sensor power supply for presence detection (already wired inside the ceiling light)
from terminal n° 1 C2M IN positive 12Vdc
(
brown color
)
> to terminal n° 1 C2F sensor (brown color)
from terminal n° 2 C2M IN negative 12Vdc (black color) > to terminal n° 2 C2F sensor (black color)
from terminal n° 3 C2F OUT NC contact line 12Vdc
(
gray color
)
> to terminal n° 3 C2F sensor (gray color
)
from terminal n° 3 C2M IN NC contact line 12Vdc
(
yellow / green color
)
> to terminal n° 4 C2F sensor (yellow / green color)
OUTPUT I°UVC corner > INPUT II° UVC corner
Following the 1st UVC corner module, connectors C1 C2 are repeated in sequence for the subsequent modules; for more specifica-
tions refer to the wiring diagrams
INPUT
C2 M
C2 x sensore
C1 M
OUTPUT
C2 F
C1 F
C2 F
C1 F
On the C2F OUTPUT connector between terminals 3 and 4 there is a jumper that closes the NC presence detection line.
The jumper must be removed if other ceiling lights are connected in sequence to give continuity to the NC line