Clearances and Projections
mINImUm pROjECTION INTO ROOm
The wall sleeve will need to be installed so that the sleeve
projects into the room a minimum amount according to
the table below.
OpTION
mINImUm
pROjECTION
INChES (mm)
WALL SLEEVE ONLY
.25 (6)
SUBBASE KIT
4.5(114)
LEVELING LEGS KIT
2 (50)
DUCT KIT
1.0 (25.4)
mINImUm CLEARANCE FOR SUbbASE, LEVELING LEGS, AND
LATERAL DUCT KIT
Installation of these kits requires drilling of mounting
holes on both sides of the wall sleeve. The minimum
required clearance distance between the wall sleeve and
floor wall is shown in the first column of the table below.
The minimum clearance between the wall sleeve and
adjacent (perpendicular) walls is shown in the second
column. If the distance between wall sleeve and adjacent
wall will be at or near the minimum clearance distance,
mount these kits on the sleeve before installing the sleeve
in the wall.
OpTION
mINImUm CLEARANCES
TO FLOOR
WALLS
INChES
INChES
WALL SLEEVE ONLY
3
0
SUBBASE KIT
3
3.25
LEVELING LEGS
3
3
DUCT KIT
3
0
DRAIN KIT
3
1.5
HARD-WIRE KIT
3
1.25
OUTSIDE WALL
ROOM SIDE
1/4”
MINIMUM
WALL
SLEEVE
MINIMUM
ROOM SIDE
PROJECTION
(SEE TABLE)
Figure 2
Minimum Projection Into Room
OUTSIDE WALL
ROOM SIDE
1/4”
MINIMUM
WALL
SLEEVE
MINIMUM
ROOM SIDE
PROJECTION
(SEE TABLE)
MINIMUM
CLEARANCE
TO FINISHED
FLOOR
(SEE TABLE)
Figure 3
Minimum Clearance From Floor
OUTSIDE WALL
INTERNAL
ADJACENT
WALL
TOP VIEW
WALL SLEEVE
MINIMUM
CLEARANCE FROM WALL
Figure 4
Minimum Clearance From Walls