17
Compass safe distance
Test object / condition
Minimum Compass safe
distance [cm]
(5.4°/H deviation or a
horizontal magnetic flux of
0.094µT)
Minimum Compass safe
distance [cm]
(18°/H deviation or a
horizontal magnetic flux of
0.313µT)
DuraPanel 7
45 cm
30 cm
DuraPanel 12
75 cm
55 cm
18
Power Consumption
Test object / condition
Ptyp [W]
Pmax [W]
DuraPanel 7
10W
15W
DuraPanel 12
20W
25W
19
In rush current
Test object / condition
[A] @24VDC
DuraPanel 7
~ 85
DuraPanel 12
~ 85
20
Troubleshooting
Problem
Cause
Solutions
No picture on display
No power connected
Apply power
Touch has an offset
No grounding of the chassis
Connect ground cable to
chassis screw
No calibration of touch
Calibrate touch
21
Servicing the unit
In case that the unit still fails after following the troubleshooting send the unit to ISIC for
repair via our RMA service on our web.
User Reference Manual – DuraPanel series