background image

ITA Series – Table Top Precision Weighing Balance

ITA Series – Table Top Precision Weighing Balance

5.3 ZERO OPERATION

Center  of  Zero  is  indicated  by  the 

annunciator                 .   You can press 

the ZERO/ENTER key to set the zero 

8

5

point from which all other weighing and counting is measured. The zero will 

function within 5% of the internal zero setting. The scale has an automatic 

auto-zeroing  function  to  account  for  minor  drifting  or  accumulation  of 

material on the platform. This auto-zero range can be configured in the user 

setup. However you may need to press the ZERO/ENTER key to rezero the 

scale if small amounts of weight are shown when the platform is empty.

5.4 MODE button 

5.4.1 COUNTING  FUNCTION  : 

When the scale is displaying 

0.000,  press  this  button 

twice, the display will show                                                                                                                                                                                               

“C   0” which is the number 

of  pieces.  You  can  select 

between  values  of  10,  20, 

50, 100, 200, 300, 400, 500, 

1000 using the Tare button 

which  are  sample  pieces. 

Once the number of pieces 

is displayed, keep the same 

number of pieces on the weighing pan and press the Zero button. 

The weight of the pieces kept on the weighing pan is displayed as the 

number of pieces selected. Simply press the Mode button once, if the 

user wants to exit the counting function to come in to the weighing 

mode. 

 

 

 

 

 

It is important to know that SLEEP mode increases the battery back-up time by 

double. The Normal backup time when the sleep mode is switched off is 30 

Hours,  and  with  the  SLEEP  mode  switched  on,  the  battery  back-up  time 

increases  to  more  than  60  Hrs.  If  the  USER  wants  to 

switch off

  the  SLEEP 

MODE for some special usage or function it can be done as follows: When the 

scale  is  in  the  weighing  mode,  Press  ZERO  and  TARE  button  together.  The 

display will show “P-TARE” Now press the ENTER button eight (8) times so that 

the display shows “SLEEP1”. 1 means the sleep mode is currently switched On. If 

the user wants to switch the sleep mode Off, press the TARE button once. The 

display will now show “SLEEP0”. Now press the ZERO button till scale comes to 

the weighing mode. Now the Sleep mode has been switched off.

6.5

LOCK  MODE  : 

By  selecting 

the Lock as “ 1 “ you can lock 

the  MODE  key  that  is  the 

mode key will not work which 

can be done as follows. When 

scale is in the weighing mode 

with  no  weight  on  the  pan, 

while  pressing  the  ZERO 

button  press  the  TARE 

button,  display  will  show  “P-

Tare”. Now press the Zero button nine (9) times so that the display shows 

“Loc  0” to enable this function that is to lock the Mode key press the Tare 

button once and the display shows “Loc  1” now press the Zero button to 

come back in the weighing mode. The Mode key has been locked and 

will not work.

 

Содержание ITA SERIES

Страница 1: ...Guide ISHTAA SCALES INC INDIA www ishtaascales com ITA ITB AS AP AP SERIES Electronic Table Top Weighing Balance ITA Series Table Top Precision Weighing Balance ITA Series Table Top Precision Weighing Balance TM 14 ...

Страница 2: ... and purposeful destruction are NOT covered by this warranty Technical Service MUST be performed by authorised staff or factory authorized personnel Manufacturer s obligation is limited to replacement of parts that have been so returned and are disclosed to Manufacturer s satisfaction to be defective The provisions of these warranty clauses are lieu of all other warranties expressed or implied and...

Страница 3: ...ernal weight Weight 4 kg Approx Pan Size 230mm x197mm Front Display Type 0 8 Bright red LED display Rear Display Optional Available with 0 56 LED Display Communication Stabilization 3 seconds Power 9V AC Adaptor or Power Cord built in battery for backup to 30hrs 40 hrs with sleep mode active Operating Temp 50 to 98 F 10 to 35 C Dimensions 245 x 210 x 140 w x d x h SOLUTION ERROR DISPLAY ERROR 8 ER...

Страница 4: ...rectly when the bubble scale is in the center of the circle The unit comes with 12V AC adaptor or 220V AC as per model specifications country of use The scale is fitted with a built in 6V 4Ah battery which provides backup of more than 35 50 hours depending on glow setting and sleep mode setting Put a known weight on the machine and make sure that the scale reads the correct weight on the display I...

Страница 5: ...ATION Internal calibration also referred as service calibration requires opening the machine and changing the jumpers It is advisable to do this step only if you have required assistance or the service personnel assisting you to do this Open the battery cover from the bottom of the machine and remove the cover and change the calibration jumper marked as CAL to ON Make sure there is nothing kept on...

Страница 6: ...e changes geographic gravity variations altitude changes and abuse are few reasons why a scale may need recalibration The scale can be calibrated using a known external weight 4 9 7 1 EXTERNAL USER CALIBRATION To start calibration turn the scale off and then turn it on During the count down press and hold down the Zero button do not release until the display shows CAL Make sure there is no weight ...

Страница 7: ...ounting function to come in to the weighing mode It is important to know that SLEEP mode increases the battery back up time by double The Normal backup time when the sleep mode is switched off is 30 Hours and with the SLEEP mode switched on the battery back up time increases to more than 60 Hrs If the USER wants to switch off the SLEEP MODE for some special usage or function it can be done as foll...

Страница 8: ...s 3d ITA Series Table Top Precision Weighing Balance ITA Series Table Top Precision Weighing Balance 6 7 6 3 LED GLOW The display GLOW strength can be increased or decreased depending upon the user requirement Increasing the GLOW of the display will effect the Battery back up time and the battery life The GLOW setting is set to minimum by Default If the user wants to increase the GLOW of the displ...

Отзывы: