34
Explanation of function keys
*RETURN: Resets the mechanical parts of the wrapper to the normal
starting position.
*FILM FEED: Feeds a sheet of film. Press the key after changing the film
roll.
*WRAP ADJUST: Provides access to tray settings to adjust wrapping
quality.
*WRAP MODE: Changes operation between Wrap & Print, Print only, and
Wrap only.
*TRAY: Enter the tray number for wrapping.
*TRAY NUMBER: Shows the current tray number. Press the key to select
a different tray from the list.
*TRAY NAME: Shows the current tray name. Press the key to select a different tray from the list.
*HEATER ADJUST: Displays the temperature of the sealing bar and fan heater. Adjust as needed.
*FILM REMOVE: In case the film has not been cut and cannot be removed, press the key to cut the film then remove it.
*WRAP STATUS: Shows the sealing bar temperature. If the color is green the selected temperature has been reached. If it is blue the sealing bar is
below the set temperature. If the color is red an error condition exists. Read the key message for details of the problem.
*VOLUME: Set the height of the product in the tray. Set the volume as High if the product blocks the infeed safety sensor and an error occurs.
*CLEANING: Moves the wrapper parts into a position for cleaning. Follow the instructions on the display.
Please refer to the Uni-7 manuals for detailed operation of the standard function keys. The following function keys are available for the WM-Nano only.
Function keys
Refer to the "Routine cleaning and maintenance" section of this manual for more details.