Manual No. 0183B
13/29
IPC Series Service Manual
3. E2ROM
clear
・
Any scene of F mode is possible.
3.1 Press the ZERO key and [ * ] key.
→
"EP-C" then "C1-1" is
displayed.
At this point, writing in E2ROM of change data in
F mode and the default value to E2ROM clear
has not been cpmlpeted. Push the memory
switch.
E2ROM clear initializes Country No., Scale No.,
Zero, and Span adjustment values. It is
necessary to set it again.
↓
4. Writing in E2ROM
・
Push the memory switch to memorize data.
After E2ROM is cleared, if writing is performed in
E2ROM without setting Country No., Scale No.
nor Zero/Span adjustment value, and the power
is turned on, "Err1" is displayed and it is not
possible to use the machine. Set C1, C2, and C3
again.
Data after E2ROM is cleared
Mode
Data
Item
C1 1
JAPAN
C2
11
Scale No.= 3kg (2g/1g) Multi interval Decimal point indication= " 0"
C3
Zero point and span adjustment value and each approximate value
F 804
Measurement
condition
2.1.10 Error No. List
Error No.
Mode
Item
Err1
At power ON
E2PROM unsetting or garbled data
Err2
At power ON
Outside start range
Err3 Test
mode
Outside range where zero point can be adjusted (original A/D 1000
count or less)
Err4
Test mode
(Original A/D 25000 count or more)
Err5 Test
mode
Outside span adjustment possible range (original A/D 33300 count
or more)
Err6
Normal mode Original A/D zero count or less
Содержание IPC 15kg
Страница 5: ...Manual No 0183B 4 29 IPC Series Service Manual 1 3 Appearance Front view Rear view Bottom view ...
Страница 6: ...Manual No 0183B 5 29 IPC Series Service Manual 1 4 Operation Panel ...
Страница 7: ...Manual No 0183B 6 29 IPC Series Service Manual 1 5 Outer Dimensions Small size Large size ...
Страница 17: ...Manual No 0183B 16 29 IPC Series Service Manual 3 1 2 Large Size 15kg 30kg ...
Страница 28: ...Manual No 0183B 27 29 IPC Series Service Manual 7 Start the test mode and perform the C3 mode span adjustment ...