Chapter 3 Test Mode
AC-4000 Service Manual No. 0181A
3-16
■
ROM SWITCH No.
Note: “ROM SWITCH” items and default value vary depending on a country where the machine is used.
•
Value in ( ) indicates the default value.
[0]: Weight data zero suppression (4)
[1]: Price data zero suppression (3)
[2]: Unit price data zero suppression (3)
[3]: DC motor (41)
[4]: Fixed price item quantity addition “0”: Real number “1”: Fixed price item quantity
[5]: Price calculation rate “0”: kg “1”: 100g
[7]: Effective day calculation
When ROM SWITCH No.7 is “0”, packed date is included. When ROM SWITCH No.7 is other
numeric than “0”, packed date is not included, therefore, add one day to the current effective day.
[8]: Time rounding calculation 0, 1 to 30 (0)
Function to increase the price based on the set minute at time now is set by standard.
(Minute/No. 8) * No. 8
[Example]
◊
Example: No. 8 = 1 min.
1
→
1 min., 2
→
2 min., ..... 59
→
59 min.
◊
Example: No. 8 = 2 min.
1
→
0 min., 2
→
2 min., 3
→
2 min., 4
→
4 min., 5
→
4 min., ..... 58
→
58 min., 59
→
58 min.
◊
Example: No. 8 = 3 min.
1
→
0 min., 2
→
0 min., 3
→
3 min., 4
→
3 min., 5
→
3 min., 6
→
6 min., ..... 57
→
57 min.
58
→
57 min., 59
→
57 min.
.
.
◊
Example: No. 8 = 30 min.
1
→
0 min., 2
→
0 min., 3
→
0 min., 4
→
0 min., 5
→
0 min., 6
→
0 min.
29
→
0 min., ..... 30
→
30 min., 31
→
30 min., ..... 59
→
30 min.
[9]: Subtotal label item name mode
0 : “sub total“ is printed.
1: Item name is printed when an item is called.
[10]: Reset key 0: Enable 1: Disable (0)
[11]: Automatic clear after totals are sent out
0: Not cleared (default) 1: Clear
[15]: Price calculation fraction processing (0)
0: 3rd decimal digit round-down 1: 3rd decimal digit round off
2: 2nd decimal digit round-down 3: 2nd decimal digit round off
[16] ITF BARCODE check digit calculation processing (0)
0: 3131. . . . . from the right 1: 1313. . . . . from the right
[17]: Head fault check (0)
0: Not available 1: Available (Set “0” for ASTRA XT)
[18]: Head fault check timing (0)
0: When calling 1: When issuing (no provision) ff: Only when changing to normal mode
[19]: Head check type (0)
0: Always at the head fault 1: When the number of head fault increases.