Boosting power using an additional power supply unit and a power injector

Always ensure that power is boosted after every 56 pixels in a daisy-
chain. An LP-700 Power Injector (P/N 83062008) can be used to 
supply boost power from an additional power supply unit (PSU - P/N 
83061701) and connect two LP-700 LED Pixel strips without splicing 
or crimping; the DMX control signal continues unbroken to each fixture 
in a daisy chain. A 3-metre (10 ft) maximum cabled-distance between 
the power supply and the first LED PIxel it supplies power to applies.  

Cutting or splicing strips

Strips can be cut to the required length, but if the system 
is installed outdoors, ensure that any exposed cable ends 
are sealed using a hot glue gun, or similar IP65-rated 
cable sealing method. Splicing strips of LP-700 LED Pixels 
together must be carried out by a qualified electrician. The arrow 
on the back of each LP-700 LED Pixel indicates the direction 
away from the power supply unit.   

When and patching, splicing or crimping power and control 
cables it is important to note that the LP-700 LED Pixel uses 

unbalanced

 DMX. DMX control only uses pins 1 and 3 of the XLR 

connectors. The pinout of the male connectors on the LP-700 
LED Pixel strips are shown here in the illustration. 

Содержание LP-700

Страница 1: ...LP 700 LED PIXEL ...

Страница 2: ...nomic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all other trademarks in this document pertaining to services or products by SGM or its affiliates and subsidiaries are trademarks owned or licensed by SGM or its affiliates or subsidiaries This edition applies to firmware version 1 or later En...

Страница 3: ...3 Contents Dimensions 4 Safety information 5 Overview 6 Installing an LP 700 LED Pixel strip 10 DMX control 12 Service 13 Specifications 14 ...

Страница 4: ...4 Dimensions Measurements in millimeters and inches in brackets Drawings not to scale ...

Страница 5: ...the AC mains supply Ensure that the power supply units are electrically connected to earth ground Do not apply power if the device or mains cable is in any way damaged Do not immerse the fixtures in water or liquid Install only in accordance with applicable building codes Do not paint cover or modify the device and do not filter or mask the light Installation must be performed by a qualified elect...

Страница 6: ...f one pixel to the center of the next pixel LP 700 LED Pixels are DMX controllable and self addressing with up to 168 individual pixels being able to be controlled using a single DMX universe Preparing for installation Each LP 700 LED Pixel strip or any length of up to 56 pixels must be connected to an LP 700 power supply unit P N 83061701 The first strip or up to 56 pixels is connected to mains s...

Страница 7: ...7 ...

Страница 8: ...AC mains power supply and supplies 18 V DC to LP 700 LED Pixels via an Injector for the first power supply in a daisy chain of LED Pixels P N 83062007 or power injector for subsequent booster power supplies in a daisy chain of LED Pixels P N 83062008 Splicing or connecting a power supply unit to mains supply or to an injector or power injector must carried out by a qualified electrician Power supp...

Страница 9: ... power to applies Cutting or splicing strips Strips can be cut to the required length but if the system is installed outdoors ensure that any exposed cable ends are sealed using a hot glue gun or similar IP65 rated cable sealing method Splicing strips of LP 700 LED Pixels together must be carried out by a qualified electrician The arrow on the back of each LP 700 LED Pixel indicates the direction ...

Страница 10: ...nce between the center of parallel rails is the pitch distance The distance between pixels pitch on a single strip is also determined by the width L of cover that is inserted between each pixel on the strip Covers are available in four lengths Width L Pitch 20 mm 0 8 in 60 mm 2 4 in 40 mm 1 6 in 80 mm 3 1 in 60 mm 2 4 in 100 mm 3 9 in 80 mm 3 1 in 120 mm 4 7 in click PITCH L ...

Страница 11: ...lded under the pixel 4 Place a cover between each pixel on the rail to ensure that the pitch is maintained and to hold the LP 700 LED PIxel strip in place 5 Place end caps at each end of the rail Two types are available the first is secured using a 4 mm 0 2 in countersunk screw while the second type can be secured using a contact adhesive 6 Ensure that any wires from the power supply are threaded ...

Страница 12: ...dress Each LP 700 LED Pixel sets its own DMX address automatically The first LP 700 LED Pixel is set to DMX address 1 and the next pixel sets itself to 4 and so on in increments of three channels per pixel For example if an LP 700 LED Pixel has a DMX address of 7 then it uses channels 7 8 and 9 The following pixel in the DMX chain will have a DMX address of 10 It is not possible to otherwise manua...

Страница 13: ... devices Do not open any of the parts in the LP 700 system as doing so is likely to cause damage Consult your SGM dealer if the device operates abnormally is defective or otherwise in need of service or repair Visit http www sgmlight com for contact information ...

Страница 14: ...gth x depth x height 1080 x 7 x 31 5 mm 42 5 x 0 3 x 1 2 in Mounting holes Ø 4 mm 0 2 in PHYSICAL LP 700 LED PIXEL COVERS Width Option of 20 40 60 or 80 mm 0 8 1 6 2 4 or 3 1 in PHYSICAL LP 700 POWER SUPPLY Length x width x height 185 x 62 5 x 40 5 mm 7 3 x 2 5 x 1 6 LIGHT SOURCE Pixel illumination source 4 x RGB SMD LED Expected LED lifetime at 70 luminous output 50 000 hours Specifications subje...

Страница 15: ... 700 LED Pixel 3 metres 10 feet OPERATING CONDITIONS Ambient temperature range Ta 40 to 50 C 40 to 122 F Maximum relative humidity 100 IP rating IP 65 PROGRAMMING AND CONTROL Control interface Unbalanced USITT DMX 512 A DMX channel requirements 3 channels per LP 700 LED Pixel self addressing LP 700 POWER SUPPLY ELECTRICAL DC power out 18 V 75 W AC mains power in 100 240 VAC nominal Output current ...

Страница 16: ...16 ORDERING INFORMATION LP 700 Power Supply Unit P N 83061701 LP 700 Injector DMX power P N 83062007 LP 700 Power Injector P N 83062008 ...

Страница 17: ...17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ......

Отзывы: