ICP 3020 / ICP 4030 iMC-P Operating instruction
page 35
S
8 Maintenance
Open the hood before switching off the machine using the mains switch. After this, this is no
more possible.
Switch of the main switch before any cleaning and any maintenance.
Also pull the power plug in order to prevent an inadvertent starting.
8.1
Cleaning the machine
-
Clean the machine regularly with a broom or vacuum cleaner of all chips (no
compressed air). That protects the mechanics against early wear.
-
With frequent machining operations and very fine chips (dusts), you should regularly
remove the cover plate of the Y-axis below the T-slot plate and remove possibly
penetrated chips and/or dusts.
-
The sealing lips include a Teflon component and require no special maintenance.
-
Clean the perspex windows with a non-abrasive fluid cleaner.
8.2
Lubrication
The shaft guides and drive shafts are provided with a long-term lubrication ex works.
Depending on the load, you should grease the shaft guides and drive shafts approx. all
500-1000 operating hours.
1
Use usual rolling bearing grease for that purpose. Ex works, the
shaft guides and shafts are lubricated
In order to lubricate the Y-axis, you must
completely push* the T-slot plate to the
front. Next, unscrew (six screws) it from the
Y-axis.
Remove the plastic plug lying under it and
lubricate through the now visible lubricating
nipple.
You reach the shaft guides through the
sealing lips.
Loosen the all around holding-down screws
in order to remove the cover sheet of the Y axis.
in all drawings is the characterize
accesses to the greasing points.
.
* You can displace the sledge using the hand if the machine is off