ICP 3020 / ICP 4030 iMC-P Operating instruction
page 18
6.3.2 Control elements on front side of the machine
No
notation
description
1
emergency stop button
Turns off the power supply for the motor power amplifiers and the working spindle in case of any danger.
This means dangers for the users health or machine safety. The integrated security circuit is applicable
category 2 with PL c according to EN 13849-1.
If you push the emergency stop switch the motor power supply will
be switched off immediately and any axes motion will be stopped.
The main power supply voltage of 115/230VAC lies still on the
device, only the motor power supply voltage for the amplifiers is
switched off.
2
power-button
Use this button to switch on motor power supply voltage for the motor power amplifiers.
Conditions for switch on:
- Main power switch on the controller back side is switched on
- Emergency stop button is pulled out
Be sure that the contacts for external emergency stop switch
on the remote connector (see chapter 6.4.2) are bridged!