Safety symbols 

 
 

  The brake chopper module IBC 10 is constructed according to the current state 

of the art and the recognized safety rules. 

 

  The device may only be operated in perfect technical condition. Disturbances 

must be corrected immediately. Children and untrained persons should not 
operate the device. 
 

  The appliance must be used only for the intended use. 

 

  All work must be performed only by authorized personnel and in accordance 

with the requirements of the electrical industry as well as the accident 
prevention regulations. 
 

  Assembly and use of resources must be performed according to the standards 

of the Declaration of Conformity. The rules and regulations as well as the limit 
values, which were kept from the manufacturer, do not protect in case of 
improper use of resources. 
 

  The device must not be exposed to high humidity and vibrations (see technical 

data). 
 

  Keep this manual in a safe place and pledge all users on their compliance!  

 

  The non-observance of this manual may result in property damage, serious 

injury and even death. 

 

 

Содержание IBC 10

Страница 1: ...isel Germany AG D 36124 Eichenzell Bürgermeister Ebert Str 40 49 0 6659 981 700 49 0 6659 981 776 Stand 07 2014 IBC 10 User manual Hardware description ...

Страница 2: ...oftware and hardware descriptions of each individual company are generally subject to protection of trademarks and patent law All rights reserved It is not permitted to reproduce or electronically process duplicate or spread any part of our prints in any way print copy etc without written permission of isel Germany AG Manufacturer isel Germany AG Bürgermeister Ebert Straße 40 D 36124 Eichenzell Te...

Страница 3: ...extmarke nicht definiert 4 2 Safety symbols 5 3 Technical Data 6 4 Connectors pin assignments Fehler Textmarke nicht definiert 7 4 1 Connection for power supply X1 Power IN 7 4 2 Connection for final stages X1 Power OUT 7 4 3 Distributor X2 A B 7 4 4 Fault output X2 C E 7 ...

Страница 4: ...ng defects and malfunctions of parts of the controller are avoided The module has an internal temperature monitoring A special floating output is suitable to evaluate the status of the external monitoring for example by a PLC or an isel residual interpret module In case of over temperature the output is open Connect the output X2 C E according to avoid over temperature of the brake chopper module ...

Страница 5: ...zed personnel and in accordance with the requirements of the electrical industry as well as the accident prevention regulations Assembly and use of resources must be performed according to the standards of the Declaration of Conformity The rules and regulations as well as the limit values which were kept from the manufacturer do not protect in case of improper use of resources The device must not ...

Страница 6: ...al Data Part no 390194 4001 Dimensions 180mm W x 110mm H x 35mm D Weight 538 g Protection class IP20 Supply voltage 24 100VDC Maximum rated current 15A Ambient temperature 5 C to 40 C Storage temperature 25 C to 70 C Relative Humidity max 95 ...

Страница 7: ... term peak loads are permitted 3 3 Distributor X2 A B These connectors are for internal use only The pin A and B are each bridged Here for example fans can be clamped in parallel 3 4 Fault Output X2 C E The terminals C and E are used for internal temperature monitoring If the terminal C connected to 24 V thus leading to the terminal E 24 V as long as the temperature limit is not exceeded Upon reac...

Страница 8: ...iBC 10 Hardware description 8 The maximum curretn IF should not exceed 200mA Evaluation of temperature error HIGH signal temperature ok Final stages Power supply ...