![Iseki TXG23 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/iseki/txg23/txg23_user-manual_2092559060.webp)
60
TXG23
ELECTRICAL SYSTEM
Battery
FIG. 76: Battery, 1, is located under engine hood in front
of instrument panel. When battery removal, electrolyte
inspection or cable cleaning is necessary, open the
engine hood.
Keep top of battery clean and ensure cable connections
are clean and tight. Debris on battery can cause dis-
charge of battery and possible source of fire.
DANGER: Batteries produce explosive hydro-
gen gas when charged. Keep all sparks and
open flame away from battery.
When necessary to disconnect battery cables, always dis-
connect the grounded (-) cable first to prevent short cir-
cuits.
Batteries contain sulfuric acid electrolyte (fluid). Wear eye
and face protection. If electrolyte comes in contact with
skin or clothes, wash immediately. Contact physician if
electrolyte is ingested or gets in eyes.
FIG. 77: Tractors are shipped with battery installed. If bat-
tery replacement should become necessary, disconnect
negative (-) cable, 1, first and then remove positive (+)
cable, 2. Loosen and remove battery securing clamp and
carefully remove battery from Tractor.
When installing battery, cable, 2, connected to starter
solenoid should be connected to positive (+) battery termi-
nal first then cable, 1, grounded to Tractor frame can be
connected to negative (-) battery terminal.
NOTE: Make sure replacement battery is of identical size
and equal capacity.
IMPORTANT: Do not reverse battery cable connections
as severe electrical system damage will
result.
FIG. 76