4.3 SLA – Active safety loop
Actively opens the Safety loop in case of a trip or a delayed trip. This option allows to shut down other modules and devices by
interrupting the SL when a trip is detected.
4.4 SLP – Internally powered safety loop
Internal current source for the Safety Loop (no galvanic isolation of the SL and the crate GND).
4.5 1CR – One current measurement range only (HP series)
Only one current measurement range for High Precision Modules.
4.6 F02 – High floating voltage
200 V isolation for Modules with FG.
4.7 F20 – Very high floating voltage
2.000 V isolation for Modules with FG.
4.8 TC – Lower temperature coefficient
Improved temperature coefficient of 10ppm/K (T10).
4.9 VLN
Reduced ripple see
.