background image

Document history

Version

Date

Major changes

1.0

16.09.2020

Relayouted version

Disclaimer / Copyright

Copyright © 2020 by iseg Spezialelektronik GmbH / Germany. All Rights Reserved.
This document is under copyright of iseg Spezialelektronik GmbH, Germany. It is forbidden to copy, extract parts, duplicate for 
any kind of publication without a written permission of iseg Spezialelektronik GmbH. This information has been prepared for 
assisting operation and maintenance personnel to enable efficient use. 

The information in this manual is subject to change without notice. We take no responsibility for any mistake in the 
document. We reserve the right to make changes in the product design without reservation and without notification to 
the users. We decline all responsibility for damages and injuries caused by an improper use of the device.

ECH 238 – 8 Slot MMS Crate | Last modified on: 16.09.2020  |  www.iseg-hv.com

2/17

www.iseg-hv.com

Содержание ECH 238

Страница 1: ...n last changed on 16 09 2020 ECH 238 8 Slot 19 MMS Crate Series for iseg MMS High Voltage Power Supply Modules up to 8 MMS High Voltage Power Supply Modules 1200W power wide range of HV modules optional fan unit optional UPS ...

Страница 2: ... Spezialelektronik GmbH This information has been prepared for assisting operation and maintenance personnel to enable efficient use The information in this manual is subject to change without notice We take no responsibility for any mistake in the document We reserve the right to make changes in the product design without reservation and without notification to the users We decline all responsibi...

Страница 3: ...y instructions DANGER DANGER Danger indicates a severe injury hazard The non observance of safety instructions marked as Danger will lead to possible injury or death WARNING WARNING Warning indicates an injury hazard The non observance of safety instructions marked as Warning could lead to possible injury or death CAUTION CAUTION Advices marked as Caution describe actions to avoid possible damages...

Страница 4: ...sures on the basis of his technical training his knowledge and experience as well as his knowledge of the relevant regulations General safety instructions Observe the valid regulations for accident prevention and environmental protection Observe the safety regulations of the country in which the product is used Observe the technical data and environmental conditions specified in the product docume...

Страница 5: ...allowed to open the unit There are no parts which can be maintained by users inside of the unit Opening the unit will void the warranty WARNING WARNING Before connecting or disconnecting HV cables or any operation on the HV output or the application the unit has to be switched off and discharge of residual voltage has to be finished Depending on application residual voltages can be present for lon...

Страница 6: ...ng of the unit WARNING WARNING The mains connection is made with basic insulation and protective conductor The device may only be operated with the protective earth conductor PE connected The protective conductor connections must be checked for proper function after installation CAUTION CAUTION When installing the units make sure that an air flow through the corresponding air inlet and outlet open...

Страница 7: ...on FAN 9 4 Operation and maintenance 10 4 1 CAN Controller 10 4 1 1 Technical data 10 4 1 2 Front Panel 11 4 1 3 External CAN Bus 12 4 1 4 SAFETY LOOP 1 12 4 1 5 SAFETY LOOP 2 12 4 1 6 Bank select switch 13 4 2 Forced air cooling 13 5 Dimensional drawings 14 6 Connectors and PIN assignments 16 7 Accesories 16 8 Order guides 16 9 Appendix 16 10 Warranty Service 17 11 Disposal 17 12 Battery 17 13 Ma...

Страница 8: ... Controller Slot 2 Technical data SPECIFICATIONS ECH 238 Slots 8 x MMS modules and 1 x Crate controller Rated AC mains input 190 264 VAC Fuse internally fused not exchangeable AC power connector IEC 320 C14T DC module supply voltages 24 V 5V DC output power 1200 W Connection CAN Cooling Optional Fan unit Operation temperature 0 50 C ambient without derating Storage temperature 20 C 70 C Floating P...

Страница 9: ... the 16A fuse which is included has to put into the fuse holder on the rear side Afterwards the battery is activated CAUTION CAUTION The crate and the included battery are free from any support If the crate is not in use for more than half a year it has to be connected to mains and switched ON for at least 8 hours so that the batteries will be charged to full capacity again After 5 years time the ...

Страница 10: ...ges and temperature of this crate Digital functions ON and OFF switch of internal supply voltages via CAN Bus in Stand by mode Power ON OFF Power cable connected and AC line is ON now the crate is in Stand by mode In Stand by mode the internal DC supply voltages can be switched ON and OFF with help of a push button even if no CAN control is present With option UPS In case of AC power failure the i...

Страница 11: ... modules HV module CAN Bus CAN IN termination or CAN OUT to more CAN nodes Crate Controller CAN Bus CAN IN termination or CAN OUT to more CAN nodes STATUS LED POWER ON 24V DC O K and Option CAN no error and Option UPS Battery load STDBY LED AC supply ON Option CAN remote control possible POWER ON ON OFF switch Supply SL1 SAFETY LOOP 1 SL2 SAFETY LOOP 2 ECH 238 8 Slot MMS Crate Last modified on 16 ...

Страница 12: ... loop then the output voltages on all channels are shut off without ramp and the corresponding bit in the Status module will be cancelled After the loop will be closed again the channels must be switched ON and a new set voltage must be given before it is able to offer an output voltage INFORMATION INFORMATION Please use a CAN Bus termination 4 1 4 SAFETY LOOP 1 IS Internal SL current 2 pin Lemo s...

Страница 13: ...r Crate 1 Control Crate 2 Control Crate 3 Control Bank Select Bank Select Bank Select Switch 0 Switch 1 Switch 2 Figure 2 Example structure Crate 4 2 Forced air cooling The crate offers an internal forced air cooling with temperature dependent speed regulation by the crate controller The fresh air intake is on the bottom for propper ventilation it needs to be sure that the airflow is not blocked I...

Страница 14: ...5 Dimensional drawings Figure 3 Dimensions ECH 238 without controller ECH 238 8 Slot MMS Crate Last modified on 16 09 2020 www iseg hv com 14 17 ...

Страница 15: ...Figure 4 controller C238 ECH 238 8 Slot MMS Crate Last modified on 16 09 2020 www iseg hv com 15 17 ...

Страница 16: ...item code parts G 2 3 8 122 xxx 00 Type System height System modules Number of available inserts Output Power Option Customized Version Crate 2 6U 3 for MMS module one significante digits 8 8 Slot two significante digits exponent For Examle 122 12 102 W 1200W UPS or FAN 00 none 9 Appendix For more information please use the following download links This document http download iseg hv com SYSTEMS M...

Страница 17: ...ste Please use the recycling and disposal facilities for electrical and electronic equipment available in your country 12 Battery INFORMATION Pb Battery contains lead Batteries and rechargeable batteries do not dispose in regular residual waste You are legally obliged to return used batteries and rechargeable batteries to a municipal collection point or to local retailers Used batteries may contai...

Отзывы: