Operators manual 

Crate ECH 128 

Crate ECH 12A 

Contents 

1. General information

2. Technical Data

3. Pin assignments

Caution! 

-The unit must not be operated with the cover removed!

- We decline all responsibility for damages and injuries caused by improper use of the system. It is

highly recommended to read the operator manual before any kind of

 

operation!

Note:

All information in this document is subject to change without notice. We take no responsibility whatsoever for
any error in this document. We reserve the right to make changes in the product design without any notification
to the users.

File name ECH12x_eng.___; Version as of July, 2011 

Via Acquanera, 29   

22100  Como

tel.  031.526.566 (r.a.)  fax  031.507.984

[email protected]   

www.calpower.it

Содержание ECH 128

Страница 1: ...emoved We decline all responsibility for damages and injuries caused by improper use of the system It is highly recommended to read the operator manual before any kind of operation Note All information in this document is subject to change without notice We take no responsibility whatsoever for any error in this document We reserve the right to make changes in the product design without any notifi...

Страница 2: ...8 slots 7 8TE 40 64mm 1 max 12TE 60 96mm 10 slots 8 TE 40 64mm AC supply voltage Before connecting to the local mains it must be proofed that the nominal line voltage of this unit is equal to the local mains Power Vin 100 240 V AC DC supply voltages 24 V up to 6 25 A 24 V up to 6 25 A Power total max 150 W INHIBIT Lemo hub on the rear connected with INHIBIT signal from all HV modules TTL level LOW...

Страница 3: ...V24 10 12 0 to 5 V 26 PWR_ V V26 10 12 24 V DC 5 max 0 8 A 28 V_ISET Setting current V28 10 12 0 to 5 V IOUT 0 to IOUTmax 1 connected with VREF through 10 kΩ n c IOUTmax is possible 30 KILL_ENA TTL level High active HV_OFF without ramp if signal INHIBIT is active Restoring the output voltage is only possible after operating KILL_ENA or PWR_ON LOW or n c HV according V_VSET or V_ISET limited to Vma...

Страница 4: ...r slots 0 to 7 H15 24 IM0 to IM7 V_i mon for slots 0 to 7 H15 14 KILLEN KILL_ENAfor slots 0 to 7 H15 30 24 V PWR_ Vfor slots 0 to 7 H15 26 GND PWR_0V for slots 0 to 7 H15 10 12 DB0 to DB7 POL for slots 0 to 7 H15 22 H15 slots 0 left to 9 right DB0 to DB7 POL for slots 0 to 7 H15 22 VSO to VS7 IS0 IS1 V_v set for slots 0 to 9 H15 20 IS2 to IS7 V_i set for slots 2 to 7 H15 28 VM0 to VM9 V_v mon for ...

Отзывы: