15
USE AND MAINTENANCE MANUAL
MILLENNIUM MY2019
EN
428001137037
8.
INSTALLATION
This manual supplies the information necessary for correct unpacking, procedures for
positioning and connection to mains electricity.
8.1
STORAGE
The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the
elements and direct sunlight, at a temperature between
0
and
+40
°C.
8.2
ENVIRONMENTAL CONDITIONS
ATTENTION
A dry room that can be ventilated is the suitable location for the appliance's installation. There should be
a good air flow around the compressor/condensing unit. Therefore the area around the unit should not be
obstructed by boxes or other objects. Place the equipment away from sources of heat (radiators, heaters
of any kind, etc.)
and far from the influence of continuous air movement (caused by fans, air conditioning
units, etc.). If it is unavoidable to install near a heat source, use a suitable insulating plate. Also avoid
exposure to direct solar irradiation
; all of this causes the temperature inside the refrigerated compartment
to rise with negative consequences on operation and energy consumption. The apparatus must not be used
outside nor be exposed to rain.
MAX
MIN
8.3
ELECTRICAL CONNECTION
ATTENTION
Check that the network voltage matches the one displayed on the identification plate of the appliance,
and that the power is adequate. Check on the socket that the power supply voltage provides rated voltage
(±10%) when you start up the compressor. The plug should be directly connected to the electrical socket. It
is forbidden to connect the plug to the socket by means of multiple socket extensions or adaptors. The plant
power supply socket must be fitted with a disconnection device from the mains electricity (dimensioned to
the load and in compliance with Standards in force), which guarantees complete disconnection in category
III (3) over-voltage conditions and therefore protects the circuits against earth faults, overloads and short
circuits. Do not route the electricity cable in passageways.
ATTENTION
Earthing is necessary and mandatory by law.
Содержание MILLENNIUM MY2019
Страница 38: ......